Ground Start Trunk
The Ground Start Trunk serves most PBX-CO connections in an analog
environment.
Figure 14: Ground Start Trunk
Table 7: Ground Start Trunk Summary
Signal
Ground Start Trunk PBX
Outgoing
Ground Start Trunk
PBX Incoming
Seize
Ring lead goes active. PBX
grounds the ring lead
Tip lead goes active; 90
Vac is applied to Ring
lead in 2 sec on, 4 sec off
cadence
Seize
Acknowledgment
Tip lead goes active; Audible
Dial Tone generated; ground
returned on tip
Tip-Ring leads activated
(shorted); Loop Current
flows in line
Digits
Loop Current toggled (Rotary)
or DTMF
-
(Sheet 1 of 2)