Technician’s Handbook
186
Peripheral Interface Cards and Modules
Table 31: Peripheral Interface Cards and Modules
Peripheral
interface
card
Devices supported Circuits
Maximum loop
resistance/loop lengths
COV Line
card
high power
Voice Mail devices
6
Loop resistance: 280
W
Loop length:
26 AWG - 1000 m (3300 ft.)
24 AWG - 1500 m (5000 ft.)
22 AWG - 2000m (6000 ft.)
DID Trunk
card
high power
Direct Inward Dial
(DID) trunks from CO
6
Loop resistance: 2450
W
Loop length:
26 AWG - 7986 m (25955 ft.)
22 AWG - 19995 m (64984 ft.)
LS/GS Trunk
card
low power
Ground start and
Loop start CO trunks
6
not applicable
LS/CLASS
Trunk card
low power
Loop Start CO trunks 8
not applicable
ONS/CLASS
Line card
low power
DTMF telephone sets
Rotary telephone sets
12
External loop resistance:
600
W
External wire resistance:
400
W
External loop length:
22 AWG - 1000 m (3300 ft.)
24 AWG - 1500 m (4875 ft.)
OPS Line
card
high power
(low power
in SX-200
EL/ML)
DTMF telephone sets
Rotary telephone sets
6
External loop resistance:
1800
W
External wire resistance:
1600
W
External loop length:
26 AWG - 5853 m (19022 ft.)
22 AWG - 15240 m (49530 ft.)
(Sheet 1 of 3)
Summary of Contents for SX-200 EL
Page 1: ...TECHNICIAN S HANDBOOK LIGHTWARE 19 RELEASE 3 0 ...
Page 11: ...Chapter 1 Introduction ...
Page 12: ......
Page 32: ...Technician s Handbook 22 ...
Page 33: ...Chapter 2 Routine Maintenance ...
Page 34: ......
Page 55: ...Chapter 3 Troubleshooting and Repair ...
Page 56: ...Technician s Handbook 46 ...
Page 88: ...Technician s Handbook 78 Figure 16 E M Trunk Type I 2 wire ...
Page 110: ...Technician s Handbook 100 ...
Page 111: ...Chapter 4 Programming ...
Page 112: ......
Page 168: ...Technician s Handbook 158 ...
Page 169: ...Chapter 5 Installation ...
Page 170: ......
Page 239: ...Chapter 6 Maintenance Commands ...
Page 240: ......
Page 258: ...Technician s Handbook 248 ...
Page 261: ...Notes ...
Page 262: ...Technician s Handbook Notes ...