Technician’s Handbook
130
Programming a Circuit Descriptor for
Hotel/Motel and ACD Datasets
1. Form 03 - COS Define
n
Select the COS number.
n
Enable the following COS Options:
—
901 - DTRX Herald
—
904 - DTRX Complete Message Text
—
906 - Data SMDR - Does Not Apply
2. Form 29 - DTE Profile
n
Select a DTE profile number. You will use this profile number in
Form 12 - Data Assignment.
n
Select the SEL. Option Subform.
n
Enable: DTRX Echoplex, Editing, and Edit Character = 127.
3. Form 11 - Data Circuit Descriptor
n
Select a Circuit Descriptor (CDN). You will use this CDN in Form
12 in the next step.
Match the CDN values to those of the selected Terminal. For example,
All Baud Rates = 9600, Parity = None, Character Length = 8, and Stop
Bits = 1.
4. Form 12 - Data Assignment
n
Select an available PLID and program the selected dataset. In
the Data Terminal Equipment profile (DTE) field enter the DTE
number you used in Form 29. Use the same CDN you used in
Form 11.
Summary of Contents for SX-200 EL
Page 1: ...TECHNICIAN S HANDBOOK LIGHTWARE 19 RELEASE 3 0 ...
Page 11: ...Chapter 1 Introduction ...
Page 12: ......
Page 32: ...Technician s Handbook 22 ...
Page 33: ...Chapter 2 Routine Maintenance ...
Page 34: ......
Page 55: ...Chapter 3 Troubleshooting and Repair ...
Page 56: ...Technician s Handbook 46 ...
Page 88: ...Technician s Handbook 78 Figure 16 E M Trunk Type I 2 wire ...
Page 110: ...Technician s Handbook 100 ...
Page 111: ...Chapter 4 Programming ...
Page 112: ......
Page 168: ...Technician s Handbook 158 ...
Page 169: ...Chapter 5 Installation ...
Page 170: ......
Page 239: ...Chapter 6 Maintenance Commands ...
Page 240: ......
Page 258: ...Technician s Handbook 248 ...
Page 261: ...Notes ...
Page 262: ...Technician s Handbook Notes ...