Technician’s Handbook
128
9. Press Enter until the [VxWorks Boot] prompt appears.
10. Type ‘@’.
11. After the Critical Alarm LED goes off, reconnect the Ethernet cable.
CDE Programming for the SX-200 IP Node
1. Form 01 - System Configuration
n
Assign IP Line Cards to slots.
2. Form 04 - System Options
n
Assign the BCC III Card to the IP Signalling Bay
—
Option 116, IP Signalling Bay (1-7) number
—
Option 117, IP Signalling Bay IP Address
—
Option 118, IP Signalling Bay Gateway Address
—
Option 119, IP Signalling Bay Subnet Mask
3. Form 47 - IP & DCHP Parameters
n
Enter the IP Controller Address. Enter the SX-200 IP Node
address.
n
Enter the DHCP Server Subnet.
n
Enter the DHCP Server Subnet mask.
n
Enter the DHCP Assignable IP Address Start. Enter the start
range of the IP phones.
n
Enter the DHCP Assignable IP Address End. Enter the end
range of the IP phones.
n
Enter the TFTP Server Address. Enter the IP address of any
SX-200 IP Node.
n
Enter the Gateway/Router IP Address.
n
Leave blank the Mitel Only field.
n
Enter the VLAN ID (optional). Enter a unique ID between 1 and
4095 for the dual-port IP phones.
n
Enter the IP phone Priority. Use a priority of 7 (highest).
Summary of Contents for SX-200 EL
Page 1: ...TECHNICIAN S HANDBOOK LIGHTWARE 19 RELEASE 3 0 ...
Page 11: ...Chapter 1 Introduction ...
Page 12: ......
Page 32: ...Technician s Handbook 22 ...
Page 33: ...Chapter 2 Routine Maintenance ...
Page 34: ......
Page 55: ...Chapter 3 Troubleshooting and Repair ...
Page 56: ...Technician s Handbook 46 ...
Page 88: ...Technician s Handbook 78 Figure 16 E M Trunk Type I 2 wire ...
Page 110: ...Technician s Handbook 100 ...
Page 111: ...Chapter 4 Programming ...
Page 112: ......
Page 168: ...Technician s Handbook 158 ...
Page 169: ...Chapter 5 Installation ...
Page 170: ......
Page 239: ...Chapter 6 Maintenance Commands ...
Page 240: ......
Page 258: ...Technician s Handbook 248 ...
Page 261: ...Notes ...
Page 262: ...Technician s Handbook Notes ...