Programming
127
Pro
gramming
n
Program the option “CLASS Trunk” in the circuit descriptor
options subform for the appropriate 4 or 8-circuit CLASS trunk.
5. Form 14, Non-Dial-In Trunks or Form 15, Dial-in Trunks
n
Program the CLASS trunks.
6. Form 04, System Options and Timers
n
Program the CLASS receivers for the LS/CLASS Trunk module.
The LS/CLASS Trunk card provides its own CLASS receivers
and does not require programming in Form 04.
Programming an SX-200 IP Node
Initializing the SX-200 IP Node
1. Ensure the SX-200 IP Node is not connected to a power source.
1. Disconnect the the Ethernet cable from the Ethernet port on the
SX-200 IP Node.
2. Using a serial cable, connect a PC to the Maintenance Port on the
IP Node.
3. Launch a data communication application, such as Hyperterminal
on the PC.
4. Set the parameters: 9600, 8, N, 1, None.
5. Plug in the SX-200 IP Node to a power source.
6. At the “Press any key to stop and auto-boot” prompt, press any key.
7. At the [VxWorks Boot] prompt, type ‘c’.
8. Press Enter to type data in the following fields:
n
inet on ethernet (e):
IP address of the SX-200 IP Node
n
gateway inet (g):
IP address of the WAN gateway or router
In Form 15 the CLASS trunk becomes a DISA trunk.
Summary of Contents for SX-200 EL
Page 1: ...TECHNICIAN S HANDBOOK LIGHTWARE 19 RELEASE 3 0 ...
Page 11: ...Chapter 1 Introduction ...
Page 12: ......
Page 32: ...Technician s Handbook 22 ...
Page 33: ...Chapter 2 Routine Maintenance ...
Page 34: ......
Page 55: ...Chapter 3 Troubleshooting and Repair ...
Page 56: ...Technician s Handbook 46 ...
Page 88: ...Technician s Handbook 78 Figure 16 E M Trunk Type I 2 wire ...
Page 110: ...Technician s Handbook 100 ...
Page 111: ...Chapter 4 Programming ...
Page 112: ......
Page 168: ...Technician s Handbook 158 ...
Page 169: ...Chapter 5 Installation ...
Page 170: ......
Page 239: ...Chapter 6 Maintenance Commands ...
Page 240: ......
Page 258: ...Technician s Handbook 248 ...
Page 261: ...Notes ...
Page 262: ...Technician s Handbook Notes ...