Programming
121
Pro
gramming
3. Enter valid Bay, Slot and Circuit numbers for the first trunk and press
the ENTER softkey.
The system displays: TO BAY: SLOT: CIRCUIT:.
4. Enter valid Bay, Slot and Circuit numbers for the last trunk and press
the ENTER softkey.
5. The system copies the values from the first trunk to all the trunks
specified in the range.
Programming a DISA Trunk
1. Form 01, System Configuration
n
Program a trunk card that meets the trunk type requirements.
2. Form 13, Trunk Circuit Descriptors
n
Select a DISA circuit descriptor to match hardware type.
3. Form 03, Class of Service
n
Assign trunk options only.
4. Form 15, Dial-In Trunks
n
Assign COS, COR, and Tenant.
n
Column N: set to 0
n
Column M: set to 0
n
Column X: leave blank
n
Assign a Trunk Name if desired. This name appears on the
consoles and on the set displays for incoming and outgoing
calls.
Recommended Options for system security include:
Form 03:
Enable Option 808 (Special DISA).
Form 04:
Enable Option 5 (Verified Account Codes) and specify a
time for Option 54 (DISA Answer Timer).
Assignment of a DISA circuit descriptor to a trunk changes the
trunk to a DISA trunk.
Assign a separate COS for the Dial-In Trunk.
Summary of Contents for SX-200 EL
Page 1: ...TECHNICIAN S HANDBOOK LIGHTWARE 19 RELEASE 3 0 ...
Page 11: ...Chapter 1 Introduction ...
Page 12: ......
Page 32: ...Technician s Handbook 22 ...
Page 33: ...Chapter 2 Routine Maintenance ...
Page 34: ......
Page 55: ...Chapter 3 Troubleshooting and Repair ...
Page 56: ...Technician s Handbook 46 ...
Page 88: ...Technician s Handbook 78 Figure 16 E M Trunk Type I 2 wire ...
Page 110: ...Technician s Handbook 100 ...
Page 111: ...Chapter 4 Programming ...
Page 112: ......
Page 168: ...Technician s Handbook 158 ...
Page 169: ...Chapter 5 Installation ...
Page 170: ......
Page 239: ...Chapter 6 Maintenance Commands ...
Page 240: ......
Page 258: ...Technician s Handbook 248 ...
Page 261: ...Notes ...
Page 262: ...Technician s Handbook Notes ...