Table 15: SX-200 IP Node Troubleshooting Table
Indication
Possible Causes
Action
WARNING: SX200
Main control not
connected or IP Node
not supported
Defective Ethernet
cables
Replace the Ethernet
Crossover cable and
CIM cable.
The Control Triple CIM
card is programmed as
a Dual CIM card.
Reprogram the Triple
CIM Card.
The CIM cable is
connected to the
wrong port on the
SX-200 IP Node
Check the hardware
connections.
The IP Bay is not
programmed in CDE
Form 01
Program the IP Bay in
CDE Form 01.
Programming in CDE
Form 04 and CDE
Form 47 is not correct
Check the
programming in CDE
Form 04 and CDE
Form 47.
(Sheet 1 of 2)