3300 ICP Hardware User Guide
66
Release 3.3
3300 ASU and Universal ASU Power
3300 ASU and Universal ASU Pin Allocations
Power Supply Input Specifications
Note:
Connector is a Standard Male IEC320 AC input.
Voltage
Universal input design, operating input voltages from 90VAC to 264VAC.
It regulates a +5, -48V, -30V, -5V, 70VAC ringing signal, and the –115VAC
Message Waiting Signal.
Current
< 1.0A RMS at 90VAC and full rated load.
Frequency
AC input frequencies from 47Hz to 63Hz.
Holdover
With an input voltage of 120VAC or 240VAC under a full rated load, the
power supply outputs remain in regulation for a minimum of 16ms after loss
of AC mains input voltage.
Brown-Out Recovery
Recovers from an AC input brown-out or sag condition automatically.
CIM Connector Pin Allocations
Pin
Signal
Pin
Signal
1
RX+
5
Not Used
2
RX-
6
TX-
3
TX+
7
Not Used
4
Not Used
8
Not Used
Note:
The 3300 Universal ASU connects to the 3300 Controller over a Category 5 Universal Twisted
Pair (UTP) cross-over cable through a CIM interface. The Category 5 cable is of the same type used
for Ethernet connections and within the cable twisted pairs are arranged as: 1,2: 3,6; 4,5; 7,8. Each
tied pair is connected to a 75 ohm resistor. The 3300 Universal ASU can be located up to 30 meters
(98.4 feet) away from the 3300 Controller. The interface employs a single standard 8-pin modular jack
consisting of 2 balanced signal pairs and is located on the front of the unit.
25 pair Connector Pin Allocations
Pin
Signal
Pin
Signal
Note:
Connection of the Tip and Ring (A and B) leads of the ONS lines and LS trunk circuits are
through a 25 pair female D-type connector.
1
ONS Tip 1
26
ONS Ring 1
2
ONS Tip 2
27
ONS Ring 2
3
ONS Tip 3
28
ONS Ring 3
4
ONS Tip 4
29
ONS Ring 4
5
ONS Tip 5
30
ONS Ring 5
6
ONS Tip 6
31
ONS Ring 6
7
ONS Tip 7
32
ONS Ring 7
8
ONS Tip 8
33
ONS Ring 8
9
ONS Tip 9
34
ONS Ring 9
10
ONS Tip 10
35
ONS Ring 10
11
ONS Tip 11
36
ONS Ring 11
12
ONS Tip 12
37
ONS Ring 12
13
ONS Tip 13
38
ONS Ring 13
Summary of Contents for Navigator 3300 ICP
Page 1: ...HARDWARE USER GUIDE ...
Page 2: ......
Page 9: ...Chapter 1 Before You Begin ...
Page 10: ...3300 ICP Hardware User Guide 2 Release 3 3 ...
Page 14: ...3300 ICP Hardware User Guide 6 Release 3 3 ...
Page 15: ...Chapter 2 Specifications ...
Page 16: ...3300 ICP Hardware User Guide 8 Release 3 3 ...
Page 95: ...Specifications Release 3 3 87 ...
Page 117: ...Chapter 3 Installing ...
Page 118: ...3300 ICP Hardware User Guide 110 Release 3 3 ...
Page 180: ...3300 ICP Hardware User Guide 172 Release 3 3 ...
Page 181: ...Chapter 4 Install Upgrades and FRUs ...
Page 182: ...3300 ICP Hardware User Guide 174 Release 3 3 ...
Page 239: ...Chapter 5 Programming ...
Page 240: ...3300 ICP Hardware User Guide 232 Release 3 3 ...
Page 243: ...Chapter 6 Troubleshooting ...
Page 244: ...3300 ICP Hardware User Guide 236 Release 3 3 ...
Page 257: ...Troubleshooting Release 3 3 249 Troubleshoot LS GS Trunk Card ...
Page 258: ...3300 ICP Hardware User Guide 250 Release 3 3 ...