15. (Optional - see Note 2) Update the firmware in the Symbol NetVision phone. Refer to the
Symbol NVP II MiNET Update Procedure.
16. (Optional - see Note 2) Complete the programming of the Symbol phone using the Symbol
NetVision MiNET Phone Administrator Tool.
Upgrade 3800 Wireless Applications Gateway to 3300 ICP Software
•
Only one 3800 Wireless Applications Gateway (WAG) can be migrated to a 3300 ICP at
a time.
•
Only D.S. Wireless phones can be migrated.
•
Migration and Configuration cannot be performed in a single task or session using the
3300 Configuration Tool.
•
After migration, configuration must be completed using System Administration Tool.
•
Data restoration automatically triggers data migration.
•
Windows 2000 users should clear the browser cache.
•
For steps requiring the Configuration Tool, refer to the Configuration Tool Help System.
•
Install the Symbol NetVision MiNET Phone Administrator Tool on a Windows NT or
Windows 2000 PC.
To transfer database from a 3800 WAG to a 3300 ICP:
1. Prepare the 3800 ICP for migration:
-
Export the Name, Number and PIN of each user with a Symbol phone to a .csv file
using the Telephone Directory Export Application in OPS Manager
-
Change OPS Manager Configuration Settings.
2. Prepare the 3300 ICP for migration:
-
Enable Options and manually reboot the system
-
Change the System name in the System Options Assignment to match that of the
system being migrated
-
Set the IP Address, Host Name, FTP Username, and FTP password to match the
Configuration Tool PC in the Controller Registry Configuration form.
3. Program 3800 WAG connectivity using the Configuration Tool. Create a Network Element
that is the same as the 3800 WAG.
4. Backup 3800 WAG database (datasave) to the 3300 Configuration Tool. The Configuration
Tool will convert the 3800 database to a 3300 database.
5. Change the Variant to 3300 ICP and change the IP Address if required.
6. Perform a Restore of the 3800 WAG converted database onto the 3300 ICP. An automatic
validation operation occurs to determine if the restore can proceed.
Note:
After the Restore and Reboot, check the log file. In the System Administration Tool,
click
Maintenance and Diagnostics
, select
Maintenance Commands
, and click
All
.
Type the following text in the Command line:
type *.dr.logfile_1
and click
Submit
.
Note 2:
The optional steps are only applicable if the database has Symbol Wireless
phones being migrated.
Summary of Contents for Navigator 3300 ICP
Page 1: ...HARDWARE USER GUIDE ...
Page 2: ......
Page 9: ...Chapter 1 Before You Begin ...
Page 10: ...3300 ICP Hardware User Guide 2 Release 3 3 ...
Page 14: ...3300 ICP Hardware User Guide 6 Release 3 3 ...
Page 15: ...Chapter 2 Specifications ...
Page 16: ...3300 ICP Hardware User Guide 8 Release 3 3 ...
Page 95: ...Specifications Release 3 3 87 ...
Page 117: ...Chapter 3 Installing ...
Page 118: ...3300 ICP Hardware User Guide 110 Release 3 3 ...
Page 180: ...3300 ICP Hardware User Guide 172 Release 3 3 ...
Page 181: ...Chapter 4 Install Upgrades and FRUs ...
Page 182: ...3300 ICP Hardware User Guide 174 Release 3 3 ...
Page 239: ...Chapter 5 Programming ...
Page 240: ...3300 ICP Hardware User Guide 232 Release 3 3 ...
Page 243: ...Chapter 6 Troubleshooting ...
Page 244: ...3300 ICP Hardware User Guide 236 Release 3 3 ...
Page 257: ...Troubleshooting Release 3 3 249 Troubleshoot LS GS Trunk Card ...
Page 258: ...3300 ICP Hardware User Guide 250 Release 3 3 ...