3300 ICP Hardware User Guide
158
Release 3.3
Install the SUPERSET HUB
Overview of the SUPERSET Hub Installation
To install the SUPERSET HUB:
1. Install the Peripheral Slot FIM Carrier in the Peripheral Cabinet.
2. Install the SUPERSET HUB unit. The supplied mounting brackets allow you to install the
unit in an equipment rack or to mount the unit on a wall.
Once you have completed these steps, you can proceed to Installing a DSU Node or return to
System Installation Overview.
WARNING: This product uses a Class 1 LED. Fiber optic sources emit infrared radiation.
This radiation is invisible to the human eye and can damage the retina. NEVER look
directly into the end of a fiber optic cable which you suspect is energized by a fiber optic
source. When working with raw fiber optic cable, be aware of fiber ends and slivers
which can puncture the skin and cause irritation.
Install the Peripheral Slot FIM Carrier
To install the Peripheral Slot FIM Carrier:
1. Attach an anti-static wrist strap.
2. Unpack the Peripheral Slot FIM Carrier and inspect it to ensure that it is not damaged.
3. Remove the Peripheral Cabinet front and rear panels.
4. Slide the Peripheral Slot FIM Carrier part-way into the first available slot from the right.
5. Remove the black plastic dust caps from the fiber optic cable connectors and from the
connector ferrules on the faceplate of the FIM.
6. Connect the fiber optic cables to the connectors on the FIM via the fiber optic access port
on the rear of the cabinet. Note: The fiber optic cable connectors have a small key that
Notes:
•
When installing the SUPERSET HUB in an enclosed rack, you MUST provide
adequate ventilation (for example, fans) to ensure that the maximum ambient
temperature inside the rack does not exceed 40ºC.
•
When mounting the SUPERSET HUB in a rack, you should ensure that a hazardous
condition is not achieved due to any uneven mechanical loading.
•
When using the SUPERSET HUB in a rack, you should consider the connection of
the equipment to the supply circuit and the effect that overloading of circuits might
have on over-current protection and supply wiring. When addressing this concern,
consider the SUPERSET HUB’s ratings label.
•
You can upgrade or replace the Fiber Interface Module in a SUPERSET HUB.
Summary of Contents for Navigator 3300 ICP
Page 1: ...HARDWARE USER GUIDE ...
Page 2: ......
Page 9: ...Chapter 1 Before You Begin ...
Page 10: ...3300 ICP Hardware User Guide 2 Release 3 3 ...
Page 14: ...3300 ICP Hardware User Guide 6 Release 3 3 ...
Page 15: ...Chapter 2 Specifications ...
Page 16: ...3300 ICP Hardware User Guide 8 Release 3 3 ...
Page 95: ...Specifications Release 3 3 87 ...
Page 117: ...Chapter 3 Installing ...
Page 118: ...3300 ICP Hardware User Guide 110 Release 3 3 ...
Page 180: ...3300 ICP Hardware User Guide 172 Release 3 3 ...
Page 181: ...Chapter 4 Install Upgrades and FRUs ...
Page 182: ...3300 ICP Hardware User Guide 174 Release 3 3 ...
Page 239: ...Chapter 5 Programming ...
Page 240: ...3300 ICP Hardware User Guide 232 Release 3 3 ...
Page 243: ...Chapter 6 Troubleshooting ...
Page 244: ...3300 ICP Hardware User Guide 236 Release 3 3 ...
Page 257: ...Troubleshooting Release 3 3 249 Troubleshoot LS GS Trunk Card ...
Page 258: ...3300 ICP Hardware User Guide 250 Release 3 3 ...