3300 ICP Hardware User Guide
94
Release 3.3
Connecting to MSDN CEPT Links (E1 Mode)
Channel mapping is required to connect with CEPT links; the external carrier must map the
channels to the CEPT link. If you set a link for E1 mode, the data on channel 24 is not inverted.
Channel 24 of the E1/T1 (DS1) link must be mapped to channel 16 of the CEPT (E1) link.
You must dedicate channels to either voice or data transmission. You must also inform the
carrier which channels are used for data transmission and which channels are used for voice
transmission. The carrier must program the voice channels for A-law to m-law conversion. Data
channels and the common channel signaling (CCS) channels must NOT be converted.
The datasets for the dedicated data channels of a link must be set for 64kbps operation. You
must also reverse the polarity of the dataset Tx and Rx leads at one of the PBXs. For
consistency, always reverse the dataset leads on the system with the E1/T1 (DS1) Formatter
card.
Basic Rate Interface (BRI) Card
The BRI card provides an interface between either six (6-circuit card) or fifteen (15-circuit card)
ISDN basic rate interface ('U'-bus) circuits and one CEPT circuit. The card converts the
Euro-ISDN or North American National ISDN-1 and ISDN-2 protocols used by the BRI circuits
to the DPNSS protocol used by the CEPT circuit.
The connections to and from the BRI card are made via the CEPT Interface Assembly mounted
at the back of the DSU cabinet. These connections are:
•
DPNSS Tx to the CEPT Interface Assembly Rx port via a BNC to BNC connector
•
DPNSS Rx to the CEPT Interface Assembly Tx port via a BNC to BNC connector
•
BRI 'U' bus tip-and-ring pairs via a D-type to Amphenol connector
•
MMI connection to the configuration terminal via an RJ45 to D-type connector
•
Provision for an RJ45 Ethernet port as a future development of the card.
Switch settings for E1 or T1 mode
Mode
Channel 24
E1/T1 Switches
Switch 1
(Link 1)
Switch 2
(Link 2)
E1 mode (compatible for connection to MSDN DS1
trunks that have been externally converted from
MSDN CEPT trunks)
data not inverted open
open
T1 mode (normal DS1 Formatter card operation)
data inverted
closed
closed
Note:
If you set a link for E1 mode, the data on channel 24 is not inverted. The external carrier must
map the channels to the CEPT link.
Note:
The BRI card, Release 2, supports both User and Network Termination; for European
installations only.
Summary of Contents for Navigator 3300 ICP
Page 1: ...HARDWARE USER GUIDE ...
Page 2: ......
Page 9: ...Chapter 1 Before You Begin ...
Page 10: ...3300 ICP Hardware User Guide 2 Release 3 3 ...
Page 14: ...3300 ICP Hardware User Guide 6 Release 3 3 ...
Page 15: ...Chapter 2 Specifications ...
Page 16: ...3300 ICP Hardware User Guide 8 Release 3 3 ...
Page 95: ...Specifications Release 3 3 87 ...
Page 117: ...Chapter 3 Installing ...
Page 118: ...3300 ICP Hardware User Guide 110 Release 3 3 ...
Page 180: ...3300 ICP Hardware User Guide 172 Release 3 3 ...
Page 181: ...Chapter 4 Install Upgrades and FRUs ...
Page 182: ...3300 ICP Hardware User Guide 174 Release 3 3 ...
Page 239: ...Chapter 5 Programming ...
Page 240: ...3300 ICP Hardware User Guide 232 Release 3 3 ...
Page 243: ...Chapter 6 Troubleshooting ...
Page 244: ...3300 ICP Hardware User Guide 236 Release 3 3 ...
Page 257: ...Troubleshooting Release 3 3 249 Troubleshoot LS GS Trunk Card ...
Page 258: ...3300 ICP Hardware User Guide 250 Release 3 3 ...