Trunking
6.2 Digital Trunks
Table 28: Digital Trunk Troubleshooting
Symptom
Probable Cause
Corrective Action
General
Excessive Bit Error
Rate.
Faulty programming.
Make sure the system is
programmed the same as the CO,
for B8Zs or AMI.
Excessive Slips.
Faulty programming.
Ensure the Network
Synchronization form is
programmed and the system is
clocking appropriately. Use the
Netsync Summary maintenance
commands to determine if
synchronization is taking place,
If not, use Net Set 1 to set off the
first clock source or NET SET
AUTO to select the best available
clock source. After you choose
a synchronization clock source
always use the NET SET AUTO
command to confirm.
System is not
Receiving Calls.
The DID trunk digit
modification number
on the Trunk Attributes
form does not have
anything programmed
in the absorb field.
It MUST have a
minimum of 0, or no
calls will be accepted.
Ensure that there is an entry in the
absorb field. It cannot be left Blank.