![Mitel Base Station Installation Manual Download Page 23](http://html.mh-extra.com/html/mitel/base-station/base-station_installation-manual_1807626023.webp)
32/1531-ANF 901 43 Uen B2 2016-04-01
Installation Guide
Base Station
21
Pin the BS3x0/BS3x2 Cable
Figure 13. Connector pinning of the Data connector
IMPORTANT: If local power supply is used, the EPP cable pair must NOT be
connected.
3.2.8 CONNECT THE BASE STATION CABLES
1
Only for IPBS4x0: If it is required that the cables enter the base station centrally
from above, guide the cables through the recess in the middle of the base station
as shown below.
2
Plug the modular jack of the data cable into one of the data/power connectors.
3
When an AC-adapter is used:
•
Plug the modular jack of the AC-adapter in one of the data/power connectors.
•
Plug the AC-adapter into a wall-outlet.
3.2.9 MOUNT THE BASE STATION
Hold the base station flat against the mounting bracket and move it downwards until it
clicks, see below.
RJ45
modular jack
EPP-b
EPP-a
SC1-a
SC0-a
SC0-b
SC1-b
NC
NC
NC
=
Not Connected
EPP
=
Express Power Pairs
SC
=
Serial Channel
008
1
5
4
3
2
6
7
8
Power cable
(if used)
Data cable
016