NOTES FOR INSTALLATION 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

AVOID IMPEDIMENTS 

AVOID DIRECT SUNLIGHT 

AVOID 
INSTALLABLE 
SURFACE 

AVOID THAT A RECEIVER CAN 
SEE MORE TRANSMITTERS 

DISTANCE OF DETECTION 

RAY 
DISPERSION 
DIAMETER 

EX

A

MP
LE

 

 O

F I

N

ST

A

LL

A

TIO

N

 H

EI

G

H

200 m 

3,2 m 

DISTANCE OF DETECTION 

RAY DISPERSION DIAMETER 

INSTALLATION - ALIGNMENT - FREQUENCY CHANGE - SENSITIVITY ADJUSTMENT 

 
1. 
2. 
 
 
 
 
1. 
 
2. 
 
 
 
 
 
3. 
 
 
 
 
 
 
 
 
 
 

 

1. 
 
2. 

INSTALLATION 

Fix the barriers so that they are aligned and wire the terminal block. 
Both on the receiver (RX) and on the transmitter (TX) check that all the dip switches are in the OFF position and power the 
modules. 

ALIGNMENT (SIGNAL LEVEL CONTROL) 

Control the red LED on the receiver module, if it is off and the buzzer does not sound (to enable the buzzer, set dip switch 9 to 
ON) the barriers are aligned. If the LED is on and the buzzer sounds, follow the procedure below: 
On the receiver, set dip switch 8 to ON and then dip switch 7 to ON, 

NOT BEFORE 7 AND THEN 8. 

Note: this is the procedure to follow even if you only want to check the signal level with aligned modules. 

A signal value will be shown on the display, then orient the receiver's optical unit in the direction of the transmitter and vice 
versa until the LED on the receiver module is off and the buzzer stops ringing. 
The values are to be considered optimal if included between 2.6 to 3.6 V, if the LED goes off even below 2.6 V it means that the 
barriers are communicating, if possible, however, try to reach a value between 2 anyway, 6 and 3.6 V. 
For vertical adjustments, act on the adjustment screw, while for horizontal adjustments, rotate the bracket (see IMAGE 1). If 
necessary, use the viewfinder to help you (see IMAGE 2). 

Once the modules are aligned, set dip switch 8 to OFF and dip switch 7 to OFF, NOT BEFORE 7 AND THEN 8. 
 
 
 
 
 
 
 

 

FREQUENCY CHANGE:  

To change the frequency which by default is 1 (dip switches 1,2 and 3 in OFF), 
follow the procedure below: 

First on the RX module and then on the TX module, using the dip switches 1,2 and 3 
set the frequency, see the table on the side for the 8 possible combinations. 

First on the RX module and then on the TX module confirm the frequency 
by setting dip switch 7 to ON and after a second repositioning it in OFF. 

ATTENTION: NEVER LEAVE DIP SWITCH 7 ON. 

 

SENSITIVITY ADJUSTMENT: 

 

Turn the trimmer                         located on the right side of the receiver to adjust the sensitivity. 

OFF   ON    OFF   ON    OFF   ON    OFF   ON 
 
OFF   OFF   ON    ON    OFF   OFF   ON    ON 
 
OFF   OFF   OFF   OFF   ON    ON    ON    ON 

FREQUENCY NUMBER (FROM 1 TO 8) 

DIP

 

1      2      3      

 

4      

  

5       6      7      8   

MIN 

MAX 

VIEWFINDER POINT OF VIEW 

IMAGE 2 

IMAGE 1 

ADJUSTABLE BRACKET 

LEFT                                        RIGHT 

Adjusting screw 

Summary of Contents for QUAD

Page 1: ...V allarme attivo MADE IN ITALY QUAD Rev 3 06 2020 MITECH srl si riserva di modificare i dati senza preavviso Pagina 1 di 2 QUAD è la mini barriera all infrarosso attivo a quattro lenti dalle dimensioni molto contenute Precablata e pronta per l installazione è composta da un unità trasmittente ed una ricevente con 8 frequenze digitali selezionabili DESCRIZIONE MORSETTIERA E DIP SWITCH RICEVITORE DE...

Page 2: ...led sul modulo ricevente sarà spento ed il cicalino smetterà di suonare I valori sono da considerarsi ottimali se compresi tra 2 6 a 3 6 V se il led si spegne anche sotto i 2 6 V significa che le barriere stanno comunicando se possibile però cercare di raggiungere comunque un valore compreso tra 2 6 e 3 6 V Per le regolazioni verticali agire sulla vite di regolazione mentre per quelle orizzontali ...

Page 3: ...tput when signal decrease ti 0 4 V will active alarm MADE IN ITALY QUAD Rev 03 06 2020 MITECH srl reserves the right to change the information in this document without warning Page 1 of 2 QUAD is the mini active infrared barrier with and small dimensions Ready for installation it consists of a transmitter and a receiver with 8 digital frequencies selectable DESCRIPTION OF CLAMP AND DIP SWITCH RECE...

Page 4: ...th aligned modules A signal value will be shown on the display then orient the receiver s optical unit in the direction of the transmitter and vice versa until the LED on the receiver module is off and the buzzer stops ringing The values are to be considered optimal if included between 2 6 to 3 6 V if the LED goes off even below 2 6 V it means that the barriers are communicating if possible howeve...

Reviews: