Gen III Tankless Misting Unit – Recommended Maintenance Procedures
MistAway
®
Systems © 2010
Gen III Tankless Unit - Recommended Maintenance Procedures
With Each Fill
•
If using a water-based insecticide, no maintenance to the unit should normally be required
with each refill.
•
If using an oil-based insecticide, follow the instructions in the Annual Maintenance
Requirements with each refill
Each Year
1. Remove and clean element in inlet water supply filter.
2. Clean batch tank and components:
a. Drain batch tank.
(MAINTENANCE Menu, DRN, Press Green
►
button for 5
seconds. Unit will mist until batch tank is empty.)
b. Access batch tank:
i. Remove fasteners securing controller to black plastic shroud. Feed controller
into cavity inside unit.
ii. Remove black plastic shroud. Lift off of posts and lean shroud (with pressure
gauge tubing intact) to left.
iii. Remove lid from batch tank.
c. Clean batch tank
, wiping out any residue
d. Clean float switch and post
– remove residue and confirm easy travel of float along
post
e. Clean or replace filter
on pump intake line
f. Replace batch tank lid, shroud and controller
3. Confirm dosing pump is working.
a. Remove controller –
with all connections secure - out of its recession in shroud.
b. Execute a MANUAL MIST.
Unit will FILL, go through an extended DOSE step,
AGITATE and MIST.
c. Confirm
dosing pump is pumping concentrate through clear tube leading to batch tank
during DOSE step.