background image

  P A G E   8   O F   1 7  

 

M I S S I ON  S OL A R  E NE R G Y L L C

 

ELECTRONIC 

versions are uncontrolled except when accessed directly from document control directory. Printed copies are uncontrolled unless verified against online document.

 

C OP YR I GH T   2 0 2 0  M I S S IO N   S OL A R   E N ER GY   L L C ,   AL L   R I G H T S   R ES E R V ED  

  REVISION: R2                                                                                                                                                                                   RELEASE DATE: 9/25/2020 

 

 

Mission Solar PV Modules have been certified to UL61730 for a 

maximum design load on the back of the module of up to 1600Pa and a 

maximum design load on the front of the module of up to3600Pa.  

 

The performance of solar modules is defined on the standard test 

conditions (STC). These conditions define performance at an incident 

sunlight of 1000 W/m2, a module temperature of 25 ± 2

o

C and AM of 1.5 

(AM = Air Mass) as per IEC60904-3. The air mass determines the 

radiation impact and the spectral combination of the light arriving on the 

earth’s surface. 

8.0

 

PRODUCT SPECIFICATION 

 

 

 

 

  

 

 

 

 

 

 

   

 

 

TABLE  1: ELECTRICAL RATINGS OF MSE PERC 72 (6BB, WHITE BACKSHEET) MODULE SERIES 

Parameters

 

MSE405SX6S 

MSE405SX6W 

MSE410SX6S 

MSE410SX6W 

MSE415SX6S 

MSE415SX6W 

MSE420SX6S 

MSE420SX6W 

MSE425SX6S 

MSE425SX6W 

Power Output 

P

max

 

Wp 

405 

410 

415 

420 

425 

Tolerance  

 

-0/+3  

-0/+3  

-0/+3  

-0/+3  

-0/+3  

Open Circuit Voltage   V

oc

 

48.56 

48.71 

48.92 

49.14 

49.28 

Short-Circuit Current 

I

sc

 

10.89 

10.93 

10.99 

11.05 

11.09 

Rated Voltage 

V

mp

 

39.59 

39.73 

39.93 

40.14 

40.27 

Rated Current 

I

mp

 

10.23 

10.32 

10.39 

10.46 

10.55 

Fuse rating   

20 

20 

20 

20 

20 

Max. System Voltage   

1,500 

1,500 

1,500 

1,500 

1,500 

 

TABLE  2: ELECTRICAL RATINGS OF MSE PERC 72 (6BB, BLACK BACKSHEET) MODULE SERIES 

Parameters

 

MSE405SX6Z

 

MSE410SX6Z

 

MSE415SX6Z

 

MSE420SX6Z

 

MSE425SX6Z

 

Power Output 

P

max

 

Wp 

405 

410 

415 

420 

425 

Tolerance  

 

-0/+3 

-0/+3 

-0/+3 

-0/+3 

-0/+3 

Open Circuit Voltage   V

oc

 

48.55 

48.70 

48.91 

49.13 

49.27 

Short-Circuit Current 

I

sc

 

10.81 

10.85 

10.91 

10.97 

11.01 

Rated Voltage 

V

mp

 

39.75 

39.88 

40.09 

40.29 

40.43 

Rated Current 

I

mp

 

10.19 

10.28 

10.35 

10.42 

10.51 

Fuse rating   

20 

20 

20 

20 

20 

Max. System Voltage   

1,500 

1,500 

1,500 

1,500 

1,500 

 

TABLE  3:  ELECTRICAL RATINGS OF MSE PERC 60 (6BB, WHITE  BACKSHEET) MODULE SERIES 

Parameters

 

MSE335SX5K 

MSE340SX5K 

MSE345SX5K 

MSE350SX5K 

MSE355SX5K 

Power Output 

P

max

 

Wp 

335 

340 

345 

350 

355 

Tolerance  

 

-0/+3 % 

-0/+3 % 

-0/+3 % 

-0/+3 % 

-0/+3 % 

Open Circuit Voltage   V

oc

 

40.35 

40.53 

40.71 

40.95 

40.99 

Short-Circuit Current 

I

sc

 

10.85 

10.91 

10.97 

11.05 

11.10 

Rated Voltage 

V

mp

 

32.89 

33.06 

33.24 

33.41 

33.51 

Rated Current 

I

mp

 

10.19 

10.28 

10.38 

10.48 

10.59 

Fuse rating   

20

 

20

 

20

 

20

 

20 

Max. System Voltage   

1,000

 

1,000

 

1,000

 

1,000

 

1,000 

 

 

 

Summary of Contents for MSE PERC 60 Series

Page 1: ...PERC Series ModuleTypes MSExxxSX6S MSExxxSX6W MSExxxSX6Z MSExxxSX5T MSExxxSX5K MSExxxSX5R Module Installation User Manual REV R2 REVISION DATE 1 29 2021...

Page 2: ...8 0 PRODUCT SPECIFICATION 8 Table 1 Electrical Ratings of MSE PERC 72 6BB White backsheet Module Series 8 Table 2 Electrical Ratings of MSE PERC 72 6BB BLACK Backsheet Module Series 8 Table 3 Electric...

Page 3: ...eys fees claims arising out of or resulting from the handling use processing alteration distributions sale or marketing of modules and this manual or any other action or inaction with regard to the mo...

Page 4: ...es with higher light intensity DC voltage of 30 Volts or higher is potentially lethal Contacting the live circuitry of a PV system operating under light can result in lethal electric shock Use insulat...

Page 5: ...emperatures Minimum ambient air temperatures 40o C 40o F Maximum ambient air temperatures 40o C 104o F 6 2 INSTALLATION CONDITION Orient the module correctly Mount the modules with the junction box in...

Page 6: ...forks to handle module pallet Do not mark the modules with sharp instruments Unpack the module pallet with care and follow the unpacking steps in this manual Be careful when unpacking transporting an...

Page 7: ...when cut Eye protection is highly recommended Lift the pallet lid and set it away from unpacking area Using a box cutter carefully cut along the corner from the top to the middle of the box on the pac...

Page 8: ...individual modules The first module must be separated and pulled out with additional care so as to not scratch the modules Continue removing modules by peeling back tape moving the module forward and...

Page 9: ...ce 0 3 0 3 0 3 0 3 0 3 Open Circuit Voltage Voc V 48 56 48 71 48 92 49 14 49 28 Short Circuit Current Isc A 10 89 10 93 10 99 11 05 11 09 Rated Voltage Vmp V 39 59 39 73 39 93 40 14 40 27 Rated Curren...

Page 10: ...ule Peak power C Voltage C Current C NOCT C MSExxxSX6S MSExxxSX6W xxx 405 425 in step of 5W xxx is standing for rated output power at STC 0 359 o C 0 261 o C 0 044 o C 44 69 o C MSExxxSX6Z xxx 405 425...

Page 11: ...le on a roof or building ensure that it is securely fastened and cannot fall as a result of wind or snow loads Provide adequate ventilation under the module for cooling 10cm minimum air space between...

Page 12: ...AD BACK OF MODULE DESIGN LOAD Bolt method SX6S SX6W SX6Z 546mm 3600 Pa 1600 Pa SX6R 506mm 3600 Pa 1600 Pa SX5T SX5K 470mm 3600 Pa 1600 Pa Clamp method SX6S SX6W SX6Z 469mm D 546mm 3600 Pa 1600 Pa 469m...

Page 13: ...of 2000m Artificially concentrated sunlight should not be directed on the module Rated electrical characteristics are within 10 percent of measured values at Standard Test Conditions of 1000 W m2 25 C...

Page 14: ...when accessed directly from document control directory Printed copies are uncontrolled unless verified against online document COP YR IGHT 2020 M ISSIO N SOL A R EN ER GY LLC ALL R IGHT S R ESERVED R...

Page 15: ...unding device manufacturer s instructions and be used with a racking system in compliance with UL Outline Standard 2703 where this module has been evaluated with that racking system 10 1 WEEB UIR The...

Page 16: ...ions with ability to work in a temperature range of at least 40o C and 90o C Install the modules so that water from rain or condensation cannot penetrate inside the cable conduits Fix cables to the st...

Page 17: ...commends that PV systems be periodically inspected by the installer or other qualified personnel The purpose of the PV system inspection is to ensure that all system components are functioning properl...

Page 18: ...ions are uncontrolled except when accessed directly from document control directory Printed copies are uncontrolled unless verified against online document COP YR IGHT 2020 M ISSIO N SOL A R EN ER GY...

Reviews: