MS-700AP(U) Series
Fire Alarm Manual Station
1
Mircom’s MS-700AP(U) Series Fire Alarm Manual Stations
provide manual fire alarm activation. These high quality, die-cast
metal stations are available as single or dual-action devices. Each
station has a permanently attached AP addressable module,
which has a pair of dials for setting the address.
Specifications & Dimensions
Compatible with Mircom Fire Alarm Control Panels
Electrical Rating:
Dimensions:
MS-702AP: 4.93” H x 3.56” W x 2.56” D
MS-710AP(U): 4.93” H x 3.56” W x 2.9” D
Converting Double Action Manual Stations to Single
Action (MS-710AP(U) only):
1.
Using a reset key, unlock and open the manual station.
2.
Remove the smaller two screws and accompanying
brackets fastening the PUSH bar.
3.
Hold the manual station vertically with one hand with the
keyhole at the bottom. Tilt the manual station towards
you and remove the PUSH bar.
Installing the manual station
This guide covers these models:
MS-702AP Intelligent Two Stage Manual Station AP
MS-710AP(U) Intelligent Dual Action Manual Station AP
The suffix
U
indicates a USA version.
Contents of kit
MS-702AP: 4 mounting screws, 2 reset keys (black), 2 stage two
keys, 1 glass rod
MS-710AP(U): 4 mounting screws, 2 reset keys (black), 1 glass
rod
A. Wiring
Note:
The maximum wire size is 12 AWG.
1.
Connect the black (-) wire from the previous station to
the terminal that is connected to the black (-) wire from
the addressable module.
2.
Connect the black (-) wire leading the next station to the
other side of the terminal that is connected to the black
(-) wire from the addressable module.
Note:
The wires must be on opposite sides of the set screw.
Refer to Figure 2 for the location of the wires.
3.
Tighten the (-) terminal.
4.
Connect the red (+) wire from the previous station to the
terminal that is connected to the red (+) wire from the
addressable module.
5.
Connect the red (+) wire leading to the next station to the
other side of the terminal that is connected to the red (+)
wire from the addressable module.
Note:
The wires must be on opposite sides of the set screw.
Refer to Figure 2 for the location of the wires.
6.
Tighten the (+) terminal.
MS-702AP
MS-710AP(U)
Nominal Operating Voltage:
15-32 VDC
Nominal Operating Voltage:
15-32 VDC
Maximum alarm current @ 24V:
5.4 mA
Maximum alarm current @ 24V:
600 µA
Average operating current @
24V: 600 µA
Average operating current @
24V: 400 µA
Notes
• Wire as shown so that supervision of connections is
maintained.
• Maximum wire size: 12 AWG
• ADA compliant.
• To be installed per ADA 4.27.1 to 4.27.4 inclusive.
• All manual fire alarm stations shall be installed as per
the specific requirements outlined in the UL/ULC codes,
as well as all other applicable national or local codes.
Final acceptance is subject to the local authority having
jurisdiction.
Screws
Screws
Figure 1: Wiring Diagram
TO ADDRESSABLE
MODULE
WRONG: BOTH
WIRES ON THE
SAME SIDE AS
THE SET SCREW
TO ADDRESSABLE
MODULE
CORRECT: BOTH
WIRES ON
OPPOSITE SIDES
OF THE SET SCREW
X
Figure 2: Close-up of terminals showing correct wiring
FROM
TO NEXT STATION OR
END OF LINE DEVICE
-
BLACK
+
RED
}
-
-
+
+
ADDRESSABLE
MODULE
PREVIOUS
STATION
}