About Your Appliance
24
1
System Messages
System messages appear on the screen to notify you of a possible problem with the
appliance.
b
If you receive a system message not listed in
on page 13, check the online
Knowledge Base at
, or contact Mirapoint Technical
Support, see
I1911
LCD Log Full. Check
SEL to review all
Errors.
LCD overflow message.
A maximum of ten error
messages can display
sequentially on the LCD.
The eleventh message
instructs the user to
check the SEL for details
on the events.
Check the SEL for
details on the events.
Remove AC power to
the appliance for 10
seconds or clear the
SEL.
I1912
SEL full. Review &
clear log.
The SEL is full of events
and is unable to log any
more.
Check the SEL for
more information and
then clear the SEL.
W1228
RAID Controller
battery capacity < 24hr.
Warns predictively that
the RAID battery has less
than 24 hours of charge
left.
Allow RAID battery to
charge to greater than
24 hours of sustained
charge.
If problem persists,
replace the RAID
battery. See
W1627
Power required > PSU
wattage. Check PSU
and config.
The system configuration
requires more power
than what the power
supply can provide.
Power off power to the
appliance, reduce the
hardware configuration
or install higher-
wattage power
supplies, and then
restart the appliance.
W1628
Performance degraded.
Check PSU and system
configuration.
The system configuration
requires more power
than what the power
supply can provide, but it
can boot if throttled.
Power off power to the
appliance, reduce the
hardware configuration
or install higher-
wattage power
supplies, and then
restart the appliance.
Table 4
LCD Status Messages (Continued)
Code
Text
Cause
Corrective Actions
Summary of Contents for RazorSafe 700
Page 10: ...4 Preface ...
Page 32: ...About Your Appliance 26 1 ...
Page 96: ...Jumpers and Connectors 90 B ...