4999DR-151-04
Miranda Densité HMP-1801 High
Definition Media Player
Requirements
• Video Server Control software option
• If you are using multiple video channels on the HMP-1801, each
channel should be assigned to a separate
Remote Port
, or a
Port
Expander
should be used.
• Serial Interface Cable (DB9 to RJ-45)
Port Connections
Cable Connectors
Figure 1
DB9 to RJ-45 Cable
Pinouts
Switcher Setup
To Set Up Communications
1.
Press
HOME
Setup
Installation
Com Setup
Type
.
• Use the
Com Port
knob to select the
REMOTE
X
port that
you connected the HMP-1801 to.
• Use the
Device
knob to select
VTR (CLIP)
.
2.
Press
Select Device
.
• Use the
Device
knob to select
VDCP
.
• Use the
VTR Preroll
knob to select
0
.
3.
Press
Com Type
.
• Use the
Type
knob to select
RS-422
.
4.
Press
Com Settings
.
• Use the
Baud
knob to select
38400
.
• Use the
Parity
knob to select
ODD
.
5.
Press
Extra Options
.
• Use the
Option
knob to select
TargetMachine
.
• Use the
Value
knob to select
HMP-1801
. The remaining
options are set automatically.
6.
Press
HOME
Confirm
.
To Set Up Video Inputs
1.
Press
HOME
Setup
Installation
BNC
BNC
Type
.
• Use the
BNC
knob to select the input BNC that the video
output of the HMP-1801 is connected to.
• Use the
Type
knob to select
VTR
.
• Use the
Video Format
knob to select the video format of the
video output of the HMP-1801.
2.
Press
More
VTR/VDCP Xpts
.
• Use the
Controller
knob to select the port on the switcher that
you assigned the HMP-1801 to.
3.
Press
VDCP Setup
.
• Use the
Channel
knob to select
1
.
• Use the
SubAddress
knob to select
0
.
4.
Press
HOME
Confirm
.
Device Setup
On the Densité HMP-1801, the following setting should be made:
•
Auto Play
: NO
•
End Behavior
: BLACK
•
Loop Count
: 1 times
Troubleshooting
If the device is communicating properly, but you cannot gain control
from the switcher, try cycling through different values for the
SubAddress, and then the Channel. The most common settings are as
follows:
• Channel set to the video channel number and SubAddress set to 0.
Switcher
Video Server
Communications
REMOTE Port
(female)
VDCP Port
(female RJ45)
Video
Input BNC
Output BNC
Switcher
HMP-1801
2 (Rx-)
2 (Tx-)
3 (Tx+)
3 (Rx+)
7 (Rx+)
1 (Tx+)
8 (Tx-)
6 (Rx-)
To Switcher
(male cable end)
To Device
(male cable end)
1
5
4
3
2
6
9
8
7
1 2 3 4 5 6 7 8