Miranda NTW-VD3232 User Manual Download Page 1

Revision: 0 

 

 

 

 
 

                                                   

Technical specifications are subject to be changed without notice 

                                                                                                                     

 

 

 
 
 
 
 
 
 
 
 

USER MANUAL 

 
 

NTW-VD3232 

Network Routing Switcher Series 

 

DIGITAL VIDEO ROUTER  -  32x32 

 
 
 

 

 

 
 

Summary of Contents for NTW-VD3232

Page 1: ...Revision 0 1 Technical specifications are subject to be changed without notice USER MANUAL NTW VD3232 Network Routing Switcher Series DIGITAL VIDEO ROUTER 32x32 ...

Page 2: ...uter configuration 7 5 1 Router address 7 5 2 Router mode 8 5 3 Vertical interval trigger 13 5 4 Power up mode 13 6 Connecting video signals to the NTW VD3232 14 7 Control and connection of Network systems interface protocol 14 7 1 Important notes regarding the Network Control Protocol 14 7 1 1 Binary Code 14 7 1 2 Acknowledge Echo 14 7 1 3 RS 422 Matrixes 14 7 1 4 Timeout 14 7 2 Basic principles ...

Page 3: ...ical specifications are subject to be changed without notice 0 Revision history Current revision of this document is the uppermost in the table below Revision Replaces Date Change Description 0 10 10 00 Initial Revision ...

Page 4: ... NTW AD3232 to create an AFV router One or several NTW 32 ProX Y remote control panels can control the NTW VD3232 as well Another unique feature of the Network 32x32 series is the possibility to reconfigure the router via the configuration switch on the back plane to create several formats of routers 32x32 Serial Digital Video 1 layer 16x16 Serial Digital Video 2 layer 10x10 Serial Digital Video 3...

Page 5: ...on the DB9 male power connector Pin 1 and 9 0V Pin 2 and 5 5V 3 Connecting the NTW VD3232 to your PC For connection to a PC with Miranda s i Control control software the RS 232 interface is used The RS 232 port on all Network devices uses the standard DCE pin out see pin out table under 4 3 A standard modem cable can be used for connecting the router to the PCs serial port The RS 232 interface for...

Page 6: ...an work together with one specific router Up to 16 single routers or combinations of routers can be controlled from one i Control control screen The MIDI bus system and all RS 232 ports interchange the system status 4 1 Several routers in one system The Network MIDI bus system allows the interconnection of up to 16 routers with different addresses in one system A combination of routers working mar...

Page 7: ...units the installer user has to assure that the bus structure is installed according to this definition The total number of MIDI devices in a MIDI chain is limited to 50 4 5 Maximum distance between MIDI devices The standard MIDI definition allows a maximum cable length of 250 meters between two devices Longer distances can be made with MIDI repeater units To avoid grounding problems all Network M...

Page 8: ...Serial Digital Video 3 layer 8x8 Serial Digital Video 4 layer Switch 5 6 on the configuration switch SW A set the router s mode The i Control software must be configured according to the mode chosen on the router The modes can be switched according to the following pattern means switch down means switch up Switch 5 6 Mode 32x32 Serial Digital Video 1 layer 16x16 Serial Digital Video 2 layer 10x10 ...

Page 9: ... 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 6 6 6 6 7 7 7 7 8 8 8 8 9 9 9 9 10 10 10 10 11 11 11 11 12 12 12 12 13 13 13 13 14 14 14 14 15 15 15 15 16 16 16 16 17 17 17 17 18 18 18 18 19 19 19 19 20 20 20 20 21 21 21 21 22 22 22 22 23 23 23 23 24 24 24 24 25 25 25 25 26 26 26 26 27 27 27 27 28 28 28 28 29 29 29 29 30 30 30 30 31 31 31 31 32 32 32 31 ...

Page 10: ... 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 6 6 6 6 7 7 7 7 8 8 8 8 9 9 9 9 10 10 10 10 11 11 11 11 12 12 12 12 13 13 13 13 14 14 14 14 15 15 15 15 16 16 16 16 SDV layer 2 Input SDV layer 2 Output 1 17 1 17 2 18 2 18 3 19 3 19 4 20 4 20 5 21 5 21 6 22 6 22 7 23 7 23 8 24 8 24 9 25 9 25 10 26 10 26 11 27 11 27 12 28 12 28 13 29 13 29 14 30 14 30 15 31 15 31 16 32 16 32 ...

Page 11: ... 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 6 6 6 6 7 7 7 7 8 8 8 8 9 9 9 9 10 10 10 10 SDV layer 2 Input SDV layer 2 Output 1 11 1 11 2 12 2 12 3 13 3 13 4 14 4 14 5 15 5 15 6 16 6 16 7 17 7 17 8 18 8 18 9 19 9 19 10 20 10 20 SDV layer 3 Input SDV layer 3 Output 1 21 1 21 2 22 2 22 3 23 3 23 4 24 4 24 5 25 5 25 6 26 6 26 7 27 7 27 8 28 8 28 9 29 9 29 10 30 10 30 ...

Page 12: ...5 5 5 5 6 6 6 6 7 7 7 7 8 8 8 8 SDV layer 2 Input SDV layer 2 Output 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 5 13 5 13 6 14 6 14 7 15 7 15 8 16 8 16 SDV layer 3 Input SDV layer 3 Output 1 17 1 17 2 18 2 18 3 19 3 19 4 20 4 20 5 21 5 21 6 22 6 22 7 23 7 23 8 24 8 24 SDV layer 4 Input SDV layer 4 Output 1 25 1 25 2 26 2 26 3 27 3 27 4 28 4 28 5 29 5 29 6 30 6 30 7 31 7 31 8 32 8 32 ...

Page 13: ...tching is enabled but a proper signal is missing the router will automatically switch without VIT The VIT can be switched according to the following pattern means switch down means switch up Switch 7 VIT disabled enabled Default is VIT enabled 5 4 Power up mode Switch 8 on the configuration switch SW A defines the power up mode The NTW VD3232 router provides two modes for powering up the system Mo...

Page 14: ... for the disconnected output Output connected to input 128 Input 128 is an internal default for the disconnect status Please see Network recommendations for use of RS 422 data routers for further information 7 1 4 Timeout The Crosspoint Status Request message has a timeout which means that you need to wait 1 second in between request messages 7 2 Basic principles Any message on any level address w...

Page 15: ...RS 232 port is used for external control of Network units The RS 232 port allows the customer to control the equipment via Miranda s i Control PC program or self defined customized solutions Connector for the RS 232 port is a DS9 female Pin 2 Tx Pin 3 Rx Pin 5 GND A standard DCE Data Communication Equipment cable can be used for connection between PC and Network equipment The connection between th...

Page 16: ...trolled kkk kkkk output number 0 output 1 127 output 128 vvv vvvv is the input which shall be connected to the chosen output vvv vvvv input number 7 5 3 Crosspoint status request This command is used for status request on Audio and Video routers 1100nnnn 0xxxxxxx nnnn is the matrix address from 0 up to 15 xxxxxxx do not carry any information The requested router Audio or Video will send its crossp...

Page 17: ...cept of digital video routers 0 C to 40 C Operating relative humidity range up to 90 non condensing 2 The equipment will operate without damage under the following environmental conditions Temperature range 10 C to 55 C Relative humidity range up to 95 non condensing 3 Electromagnetic compatibility conditions Emissions EN 55103 1 Directive 89 336 EEC Immunity EN 55103 2 Directive 89 336 EEC Electr...

Page 18: ...pport networkgroup no Declaration of Conformity with CE This apparatus meets the requirements of EN 55103 1 November 1996 with regard to emissions and EN 55103 2 November 1996 with regard to immunity it thereby complies with the Electromagnetic Compatibility Directive 89 336 EEC Regarding electrical safety we refer to the declaration of conformity provided with the external power supply ...