background image

OWNER’S MANUAL

Split Air Conditioner

Thank you for choosing our product.

For proper operation, please read and keep this manual carefully. 

If you have lost the Owner’s Manual, please visit: www.mirageappliances.us

IAEH121A / OAEH121A

IAEH241A / OAEH241A

CONFORMS TO 

UL STD. 1995

CERTIFIED TO 

CSA STD. C22.2

NO. 236

Summary of Contents for IAEH121A

Page 1: ... choosing our product For proper operation please read and keep this manual carefully If you have lost the Owner s Manual please visit www mirageappliances us IAEH121A OAEH121A IAEH241A OAEH241A CONFORMS TO UL STD 1995 CERTIFIED TO CSA STD C22 2 NO 236 ...

Page 2: ...at if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related information used to indicate risk of property damage Indicates a hazard that would be assigned a signal word WARNING or CAUTION DANGER WARNING CAUTION NOTICE ...

Page 3: ...Vacuum pumping Leakage detection Check after installation Test and operation Test operation Attachment Configuration of connection pipe Pipe expanding method 1 6 8 8 9 13 15 15 16 16 19 23 24 25 25 26 27 32 35 35 36 36 37 39 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have ...

Page 4: ...se electric shock If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Do not wash the air conditioner with water to avoid electric shock Do not spray water on indoor unit It may cause electric shock or malfunction After removing the filter do not touch fins to avoid injury Do not use fire or hair dryer to...

Page 5: ...er cord is overheating or damaged There s abnormal sound during operation Circuit break trips off frequently Air conditioner gives off burning smell Indoor unit is leaking If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard When turning on or turning off the unit by emergency operation switch please press this switch with an insulating o...

Page 6: ...ircuit break with suitable capacity please note the following table Air switch should be included magnet buckle and heating buckle function it can protect the circuit short and overload Air Conditioner should be properly grounded Incorrect grounding may cause electric shock Don t use unqualified power cord Make sure the power supply matches with the requirement of air conditioner Unstable power su...

Page 7: ...ed personnel only The air conditioner is a first class electric appliance It must be properly grounding with specialized grounding device by a professional Please make sure it is always grounded effectively otherwise it may cause electric shock The yellow green wire in air conditioner is grounding wire which can t be used for other purposes The grounding resistance should comply with national elec...

Page 8: ...cause personal injury or damage Select a location which is out of reach for children and far away from animals or plants If it is unavoidable please add the fence for safety purpose The indoor unit should be installed close to the wall Working temperature range Indoor side DB WB F Outdoor side DB WB F Maximum cooling 80 67 115 75 Maximum heating 80 75 65 The operating temperature range outdoor tem...

Page 9: ...or Unit Outdoor Unit Actual product may be different from above graphics please refer to actual products air inlet panel aux button horizontal louver air outlet NOTICE remote control air inlet Connection wire air outlet ...

Page 10: ...or some model heating indicator temp indicator cooling indicator power indicator receiver window drying indicator display For some model heating indicator temp indicator cooling indicator power indicator receiver window drying indicator G W R Power LED color indicator Green status ON Red status OFF Mode LED color indicator White W Cool Mode Red R Heat Mode Green G Dry Mode O W R Power LED color in...

Page 11: ...utton TEMP button I FEEL button LIGHT button CLOCK button TIMER ON TIMER OFF button SLEEP button Send signal Turbo mode 46 F heating function Set temperature Set time TIMER ON TIMER OFF Child lock Up down swing Set fan speed Light Temp display type Set temp Outdoor ambient temp Indoor ambient temp Sleep mode Clock Heat mode Fan mode Dry mode Cool mode Auto mode Operation mode I feel ...

Page 12: ... corresponding set function icons Press this button can turn on or turn off the air conditioner After turning on the air conditioner operation indicator on indoor unit s display is ON green indicator The colour is different for different models and indoor unit will give out a sound Press this button to select your required operation mode When selecting auto mode air conditioner will operate automa...

Page 13: ...ir conditioner will select proper fan speed automatically according to ex factory setting Fan speed under dry mode is low speed Press this button can select up down swing angle Fan blow angle can be selected circularly as below When selecting air conditioner is blowing fan automatically Horizon tal louver will automatically swing up down at maximum angle When selecting air conditioner is blowing f...

Page 14: ...to CLOCK TIMER ON TIMER OFF buttons Under COOL HEAT or DRY mode press this button to start up sleep function icon is displayed on remote controller Press this button again to cancel sleep function and icon will disappear By pressing this button you can see indoor set temperature indoor ambient temperature or outdoor ambient temperature on indoor unit s display The setting on remote controlleris se...

Page 15: ...e indoor unit can receive the signal sent by the remote controller Press this button to turn off display light on indoor unit icon on remote controller disappears Press this button again to turn on display light icon is displayed Press this button to set clock time icon on remote controller will blink Press or button within 5s to set clock time Each pressing of or button clock time will increase o...

Page 16: ...off according to setting time ON OFF button has no effect on setting If you don t need this function please use remote controller to cancel it Function introduction for combination buttons Energy saving function Under cooling mode press TEMP and CLOCK buttons simultaneously to start up or turn off energy saving function When energy saving function is started up SE will be shown on remote controlle...

Page 17: ...s TURBO button and the remote controller won t send signal Sleep function and 46 F heating function can t operate at the same time If 46 F heating function has been set under cooling mode press sleep button will cancel 46 F heating function If sleep function has been set under cool ing mode start up the 46 F heating function will cancel sleep function Child lock function Press and simultaneously t...

Page 18: ...ce two 7 AAA 1 5V dry batteries and make sure the position of polar and polar are correct 3 Reinstall the cover of battery box During operation point the remote control signal sender at the receiving window on indoor unit The distance between signal sender and receiving window should be no more than 8m and there should be no obstacles between them Signal may be interfered easily in the room where ...

Page 19: ...o mode Use insulated object to press the auto button Clean and Maintenance Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not wash the air conditioner with water to avoid electric shock Do not use volatile liquid to clean the air conditioner Clean surface of indoor unit When the surface of indoor unit is dirty it is recommended ...

Page 20: ...ery dirty use the water below 110 F to clean it and then put it in a shady and cool place to dry Install filter Install the filter and then close the panel cover tightly The filter should be cleaned every three months If there is much dust in the operaion environment clean frequency can be increased After removing the filter do not touch fins to avoid injury Do not use fire or hair dryer to dry th...

Page 21: ... and Maintenance Checking before use season 1 Disconnect power supply 2 Clean filter and indoor unit s panel 3 Check whether mounting bracket for outdoor unit is damaged or corroded If yes please contact dealer Checking after use season for recovery 1 Many packing materials are recyclable materials Please dispose them in appropriate recycling unit 2 If you want to dispose the air conditioner pleas...

Page 22: ...on troller low fuzzy display and no display Check the batteries If the power of batteries is too low please replace them No display when operating remote controller Check whether remote control ler appears to be damaged If yes replace it Fluorescent lamp in room Take the remote controller close to indoor unit Turn off the fluoresent lamp and then try it again Indoor unit can t receive remote contr...

Page 23: ... indoor unit s air outlet Indoor temperature and humidity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Set tempera ture can t be adjusted Unit is operating under auto mode Temperature can t be adjusted under auto mode Please switch the operation mode if you need to adjust temperature Your required temperature ex...

Page 24: ...it again Outdoor unit has vapor Heating mode is turned on During defrosting under heating mode it may generate vapor which is a normal phe nomenon Water flowing noise Air conditioner is turned on or turned off just now The noise is the sound of re frigerant flowing inside the unit which is a normal phenomenon Cracking noise Air conditioner is turned on or turned off just now This is the sound of f...

Page 25: ...nit If not please contact qualified professionals for service C5 Please contact qualified professionals for service F1 Please contact qualified professionals for service F2 Please contact qualified professionals for service Note If there re other error codes please contact qualified professionals for service When below phenomenon occurs please turn off air conditioner and disconnect power immediat...

Page 26: ... v e 20 Air inlet side 0 0 Space to the obstruction Air outlet side 8 0 Above Above 12 1 2 Space to the wall Drainage pipe Abov e 20 At least 8 At least At least 118 Space to the ceiling Space to the obstruction At least At least Space to the wall Space to the wall ...

Page 27: ...ture resulting in injury During refrigerant recovery make sure that liquid valve and gas valve are fully closed and power is disconnected before detaching the connec tion pipe If compressor starts running when stop valve is open and connection pipe is not yet connected air will be sucked in and cause pressure rise or compressor rupture resulting in injury When installing the unit make sure that co...

Page 28: ...should be no obstruction near air inlet and air outlet 2 Select a location where the condensation water can be dispersed easily and won t affect other people 3 Select a location which is convenient to connect the outdoor unit and near the power socket 4 Select a location which is out of reach for children 5 The location should be able to withstand the weight of indoor unit and won t increase noise...

Page 29: ...by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 8 The temperature of refrigerant circuit will be high please keep the interconnection cable away from the copper tube 9 The appliance shall be installed in accordance with national wiring regulations Grounding requirement 1 The air conditioner is the first class electric appliance It must be properly gr...

Page 30: ...icle is loose please drill another fixing hole nearby Step three open piping hole 1 Choose the position of piping hole according to the direction of outlet pipe The position of piping hole should be a little lower than the wall mounted frame shown as below 2 Open a piping hole with the diameter of Φ2 5 or Φ3 on the selected outlet pipe position In order to drain smoothly slant the piping hole on t...

Page 31: ...ading out the pipe from left or right please cut off the corresponding hole on the bottom case Step five connect the pipe indoor unit 1 Aim the pipe joint at the corre sponding bellmouth 2 Pretightening the union nut with hand 3 Adjust the torque force by refer ring to the following sheet Place the open end wrench on the pipe joint and place the torque wrench on the union nut Tighten the union nut...

Page 32: ...ll drain hose 1 Connect the drain hose to the outlet pipe of indoor unit 2 Bind the joint with tape outlet pipe drain hose drain hose tape outlet pipe drain hose insulating pipe Note Add insulating pipe in the indoor drain hose in order to prevent condensation The plastic expansion particles are not provided Step seven connect wire of indoor unit 1 Open the panel remove the screw on the wiring cov...

Page 33: ...rew 5 Close the panel Note the wiring board is for reference only please refer to the actual one Note All wires of indoor unit and outdoor unit should be connected by a professional If the length of power connection wire is insufficient please contact the supplier for a new one Avoid extending the wire by yourself For the air conditioner with plug the plug should be reachable after finishing insta...

Page 34: ...rd and control wire can t be crossed or winding The drain hose should be bound at the bottom Step nine hang the indoor unit 1 Put the bound pipes in the wall pipe and then make them pass through the wall hole 2 Hang the indoor unit on the wall mounting frame 3 Stuff the gap between pipes and wall hole with sealing gum 4 Fix the wall pipe 5 Check if the indoor unit is installed firmly and closed to...

Page 35: ...nstalled at least 2 above the floor in order to install drain joint For the unit with cooling capacity of 2300W 5000W 6 expansion screws are needed for the unit with cooling capacity of 6000W 8000W 8 expansion screws are needed for the unit with cooling capacity of 10000W 16000W 10 expansion screws are needed Step two install drain joint Only for cooling and heating unit 1 Connect the outdoor drai...

Page 36: ...n nut with torque wrench by referring to the sheet below Hex nut diameter Tightening torque lbft Φ 1 4 13 Φ 3 8 30 Φ 1 2 40 Φ 5 8 48 Φ 3 4 48 Step five connect outdoor electric wire 1 Remove the wire clip connect the power connection wire and signal control wire only for cooling and heating unit to the wiring terminal according to the color fix them with screws Note the wiring board is for referen...

Page 37: ...utdoor unit is higher than the wall hole you must set a U shaped curve in the pipe before pipe goes into the room in order to prevent rain from getting into the room Outdoor Condensate Drainage only for Heat pump unit During heating operation the con densate and defrosting water should be drained out reliably through the drain hose Install the outdoor drain connector in a Φ25 hole or Φ42 hole on t...

Page 38: ...gas and liquid valves completely to let refrigerant fill the system up 6 Put valves cap back and do the same with nut of suction port once you have removed manifold Leakage detection 1 With leakage detector Check if there is leakage with leakage detector 2 With soap water If leakage detector is not available please use soap water for leakage detection Apply soap water at the suspected position and...

Page 39: ...w the specification It may cause malfunction or damaging the parts Is there any obstruction in the air inlet and outlet It may cause insufficient cooling heat ing capacity The dust and sundries caused during installa tion are removed It may cause malfunction or damaging the parts The gas valve and liquid valve of connection pipe are open completely It may cause insufficient cooling heat ing capacity ...

Page 40: ... ft 65 ft 48000Btu h 14064W 98 ft 65 ft 4 The additional refrigerant oil and refrigerant charging required after prolonging connection pipe After the length of connection pipe is prolonged for 32 ft at the basis of standard length you should add 0 17 oz of refrigerant oil for each additional 16 ft of connection pipe The calculation method of additional refrigerant charging amount on the basis of l...

Page 41: ...A and R134a Diameter of connection pipe Outdoor unit throttle Liquid pipe Gas pipe Cooling only oz ft Cooling and heating oz ft Φ 1 4 Φ3 8 or Φ1 2 0 161 0 215 Φ1 4 or Φ3 8 Φ5 8 or Φ3 4 0 161 0 537 Φ1 2 Φ3 4 or Φ7 8 0 322 1 290 Φ5 8 Φ1 or Φ1 1 4 0 645 1 290 Φ3 4 2 688 2 688 Φ7 8 3 763 3 763 ...

Page 42: ...emove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe E Expand the port Expand the port with expander Note A is different according to the diameter please refer to the sheet below Outer diameter 1 4 3 8 1 2 5 8 Max Min 0 051 0 027 0 062 0 039 0 070 0 039 0 094 0 086 A mm F Inspection Check the quality of expand ing port If there is any blemish expand...

Page 43: ...E5 Compressor demagnetization protection HE Over phase current protection P5 PFC protection Hc Compressor desynchronizing H7 IPM Temperature Protection P8 IPM Current protection H5 Over power protection L9 Compressor phase loss reversal protection Ld System charge shortage or blockage protection F0 Frequency restricted reduced with whole unit current protection F8 Capacitor charging error PU Frequ...

Page 44: ...6700 Gateway Park Dr Unit 6 San Diego CA 92154 Ph 619 426 0033 mirageappliances us ...

Reviews: