Mirage C-22-G Instruction Manual Download Page 1

C-22-G Instruction Manual 

 

R. F. Amplifier 

C-22-G 

R.F. AMPLIFIER

 

 
The Mirage C-22-G is the next generation of Power Amplifiers for 220 - 225 MHz.  New 
features make it the most useful and versatile amplifier available.  Features include 
automatic power shut-down circuitry for protection against excessive R.F. power input.  
A newly designed GaAsFET receive pre-amp provides high gain and low noise 
amplification for weak signal applications.  The pre-amp includes a selectable attenuator 
to reduce signal output level.  This is useful in preventing Receiver Overload and 
subsequent Intermodulation Distortion caused by strong signals.  The Mirage C-22-G is 
capable of FM, SSB, and CW operational modes. 
 

SPECIFICATIONS 

Frequency Range ....................................................... 220 - 225 MHz 

R.F. Input Power (Drive)........................................... 0.4 - 4 Watts (5 Watts max.) 

R.F. Output Power..................................................... 20 Watts with 2 Watts drive 

Duty Cycle................................................................. Intermittent (ICAS) 

Modes ........................................................................ FM, SSB, CW 

Receive Pre-amp ....................................................... GaAsFET, Gain 21/15 dB-Nominal.  

Noise figures less than 0.6 dB. 1 dB 
compression point greater than -13 
dBm input (Nominal) 

R.F. Input Power Shutdown Point............................. In excess of 5 Watts nominal 

Keying ....................................................................... Automatic (R.F. sensing) 

Input/Output Impedance............................................ 50 Ohms 

R.F. Connectors......................................................... SO-239 (UHF) 

Supply Voltage .......................................................... 13.8 VDC (for full R.F. power 

 output) 

Supply Current .......................................................... 4 Amps (nominal) 

Fuse ........................................................................... Low voltage, fast blow. 7-1/2 Amps 

Physical Dimensions ................................................. 3-1/2 x 2 x 7 inches 

Weight ....................................................................... 1 1/4 pounds 
 

INSTALLATION 

The Mirage C-22-G may be mounted using the brackets supplied or simply placed in a 
convenient operating position.  In either case, there must be adequate ventilation for the 
finned heat-sink.  This generally means at least 1 inch clearance from the sink to any 
surrounding enclosure and an unobstructed flow from the front to the back of the sink.  

CAUTION:  With extended use the heat sink becomes very hot.

  If it is necessary to 

extend the D.C. power leads, use wire of the same gauge in order to avoid a voltage drop 