Page 1: ...These instructions are to be left with the user Mira Event XS manual Power Shower Installation and User Guide...

Page 2: ...lation Requirements 10 1 General 10 2 Electrical 10 3 Plumbing 11 4 Installation Diagrams 13 Installation 14 1 Before You Start 14 2 Configuring Inlet Supplies 15 3 Shower Installation 17 Commissionin...

Page 3: ...ves The shower control is supplied with Mira Logic power shower fittings These fittings consist of an adjustable spray handset with four different spray actions start champagne massage and economy fle...

Page 4: ...Mira Event XS if water leaks from the unit maintenance will be required before the Mira Event XS can be safely used 1 7 DO NOT allow the Mira Event XS to be run dry 1 8 DO NOT fit any form of outlet f...

Page 5: ...Scotland ECAS 2 6 The plumbing installation must comply with Water Supply Regulations Bye laws Scotland Building Regulations or any particular regulations and practices specified by the local water c...

Page 6: ...part names and to confirm that the parts are included Documentation q 1 x Guarantee Registration Document q 1 x Installer Product Check List q 1 x Event XS M Manual Power Shower q 1 x Push Fit Release...

Page 7: ...7 Dimensions All dimensions in millimetres 310 84 115 80 66 28 20 210...

Page 8: ...0 008 bar or 80 mm required to prime the integral centrifugal pump The minimum static pressure will increase for long supply pipe lengths Refer to section Installation Requirements Plumbing 1 7 Minim...

Page 9: ...each pole 3 2 Power supply connection The Mira Event XS is fitted with a terminal block which will accept cable up to 2 5 mm Minimum cable size cross sectional area required under normal installation...

Page 10: ...drain from behind the appliance 1 8 When fitting the Mira Event XS with wall entry inlet supplies it is recommended that the supply pipework is sealed to the wall to prevent water from leaking back in...

Page 11: ...ne plastic pipe suitable for hot water is recommended to enhance the appearance of the finished installation Internal pipe supports not supplied should be used with this type of pipe 3 8 Only use the...

Page 12: ...0 x 20 D x 20 x 20 15 mm Elbow No of Elbows x 55 No of Elbows x 55 22 mm Elbow No of Elbows x 15 No of Elbows x 15 Add the minimum effective head required 80 Add the minimum effective head required 80...

Page 13: ...ecause A drop in cylinder water level could expose a top entry immersion element if fitted Air in water solution gathers at the edge of the cylinder and in the centre during the heating process before...

Page 14: ...ide where to site the Mira Event XS power shower It should be positioned at a height convenient for all the family The fittings should be fitted so the handset sprays away from the Mira Event XS eithe...

Page 15: ...ports of the inlet manifold Fit half insert in the top inlet of the case Fit full insert in the bottom inlet of the case Bottom Entry Inlet Fit blanking plugs to top ports of the inlet manifold Fit fu...

Page 16: ...b concealing cap 2 2 Use the push fit release tool to lever off the temperature knob Note It will be easier to lever off the temperature control knob with the push fit release tool inserted under the...

Page 17: ...or the fitting and removal of the cover Ensure that when the hose retaining ring is placed on the lowest position on the slide bar there is a minimum distance of 25 mm between the handset and the bath...

Page 18: ...ever these methods of fixing are beyond the scope of this guide Warning Ensure the marked fixing points are not inline with buried cables and pipes before drilling 3 7 Drill 9 5 mm holes and fit the r...

Page 19: ...t manifold due to the water supply pressure 3 11 Ensure that the end of the supply pipework is cut squarely and free from burrs which can damage the inlet manifold seals Chamfer the end of the pipe to...

Page 20: ...uctors of the electrical supply cable to the terminal block The supply cable earth connector should be sleeved 3 16 Turn the flow spindle fully clockwise so that the flat is facing towards11 o clock 3...

Page 21: ...itted 1 3 Turn the water supplies fully on at the isolating valves Check that water is not leaking from the bottom of the case 1 4 Switch on the electrical supply to the product 1 5 Turn the flow cont...

Page 22: ...flow Turn anticlockwise for warmer water Turn clockwise for cooler water Turn fully clockwise to stop the flow of water 1 1 From the stop position turn the flow control knob anticlockwise to start the...

Page 23: ...nd temperature unstable Spray plate blocked Inlet filter blocked Isolating valve partially closed Plumbing system fault Clean spray plate Refer to the Installation User guide supplied with the shower...

Page 24: ...r is too high up the pipe Refer to plumbing system diagrams in section Installation Requirements Note the 1 metre hot take off dimension Consider increasing cold feed pipe to cylinder to 28 mm diamete...

Page 25: ...ra for further advice Pump speed does not change PCB failure Renew the PCB Low or no water flow Isolating valves closed Inlet filters blocked Check valve fitted incorrectly Appliance sited above cold...

Page 26: ...sives and chemical substances and should not be used for cleaning plated or plastic fittings These finishes should be cleaned with a mild washing up detergent or soap solution and then wiped dry using...

Page 27: ...emoved 4 1 Remove the front cover refer to section Maintenance 3 Front Cover Removal 4 2 Unscrew the retaining screw and remove the filter cap Note A small amount of trapped water may drain from the m...

Page 28: ...inlet manifold and mixer assembly 5 8 The ports adjacent to the mixer assembly contain the inlet check valves The check valves can be removed and replaced if required Ensure the check valve is insert...

Page 29: ...erse order 5 11 Restore the water supplies and check for any leaks 5 12 Refit the cover and secure by tightening the three cover retaining screws refit the temperature control knob and concealing cap...

Page 30: ...30 Wiring Diagram MOTOR BROWN BROWN ORANGE BLUE THERMAL TRIP POTENTIOMETER SWITCH ON OFF SOLENOID VALVE L N E...

Page 31: ...l 453 07 Inlet Manifold Assembly identified B 453 08 PCB Assembly Power 453 11 Harness Assembly Manual identified C 453 13 Solenoid Valve Assembly identified D 453 14 Filter Cap Assembly 453 15 Seal P...

Page 32: ...0 Chrome 2 1616 031 Mira s new Everclear range has been specially designed for hard water areas and reduces the risk of lime scale build up Shower Seat White 2 1536 128 White Chrome 2 1536 129 For use...

Page 33: ...notes...

Page 34: ...notes...

Page 35: ...notes...

Page 36: ...rantees A selection of protection plans are available that enable you to cover repair bills for the life of your policy excludes Eire Ring 01922 471763 for more details Helpdesk Service Our dedicated...