Optosense LLC
USER MANUAL
Design department
MIPEX-04 ULTRA-LOW POWER INFRARED GAS SENSOR
ESAT.100000.00.02 UM
Revision 02
December 12th, 2016
Page 7 of 41
THE SOLE PROPERTY OF OPTOSENSE LLC. ANY REPRODUCTION WITHOUT THE WRITTEN PERMISSION OF OPTOSENSE LLC IS PROHIBITED.
Table 4. Electrical specifications, marking and standards compliance
Operating supply voltage, VDC
+2.8
…+5.0
Max supply voltage, VDC
+5.5
Communication interface
UART
Average current,
μA
35
Marking and standards compliance
Sensor is not certified.
It is designed in accordance with various international
standards.
IEC/EN 60079-0, IEC/EN 60079-11:
Explosion protection level
– “ia”;
Hazardous area class (Electrical equipment group)
– “I”
and “IIC”;
Temperature class
– “T6”.
UL913, CAN/CSA-C22.2 No. 157-92:
Class I, Division 1, Group A, B, C, D.