background image

6

5.  AC Fault LED (Yellow/Red): Yellow when commercial input voltage is lost or too

low or input frequency shifts drastically and unit switches to inverter mode.  Red
when commercial input voltage is

 

too high and unit switches to inverter

 

mode

.

Both stay on until fault is cleared.  Off as long as commercial voltage is present
and in range, and frequency is stable.

6.  Battery Status LED (Yellow/Red): Yellow at low battery warning.  Red at low

battery cutoff for one (1) second. Off otherwise.

7.  Overload LED (Red): On when inverter shuts down because of unit overload or

because input frequency is far out of range, off otherwise.  Overload LED stays
on until unit power switch is turned off and back on with conditions corrected.

8.  Fuse/Breaker Fault LED (Red): On when AC fuse (AT650, AT800 or AT2300) is

blown or AC Breaker (AT1200 or AT1600) is tripped, off otherwise.

9.  Output Receptacles, 120VAC units: 4 NEMA 5-15R receptacles on all units

except AT2300.  AT2300 has 6.

10.  Power Cord, 120VAC units: AWG 18/3 (AT650 and AT800) or AWG 14/3

(AT1200 and AT1600) SJT with NEMA 5-15P Plug (standard) or AWG 12/3 SJT
(AT2300) with NEMA L5-30P Plug.

11.  Input Fuse Holder/Breaker: At650, AT800 and AT2300 units use fuse and fuse

holder at input.  AT1200 and AT1600 units use AC circuit breaker at input.

12.  LAN Communications Port (DB9 Female):  Standard on all units.

13.  Cooling Fan: Models AT1200, AT1600 an AT2300 only.  Smaller models are

convection cooled.

14.  Audible Alarm (Internal): Sounds twice every two seconds in normal inverter

mode after an initial five (5) second delay; sounds four (4) times per second at
low battery warning.

GS MODELS

Each GS model is the same as the comparable AT series model except for power plugs and
receptacles.  GS units use global sockets (2 on GS650 and GS800, and 4 on GS1200 and larger
units) on all models instead of the receptacles shown in unit pictorials.  These models use an
IEC320 power cord socket with user selectable international cord sets.

INSTALLATION AND PRELIMINARY TESTING

  Ensure that the UPS power switch is off ("0" position) and no load is connected to the

UPS output receptacles.

  Plug the UPS power plug into a grounded commercial power receptacle with proper

supply voltage and frequency for the specific UPS model under test.  For GS models,
first plug the cord set into the UPS IEC320 socket.

Summary of Contents for AT1200

Page 1: ...MODELS DESCRIBED IN THIS MANUAL AT650 GS650 650VA AT800 GS800 800VA AT1200 GS1200 1200VA AT1600 GS1600 1600VA AT2300 GS2300 2300VA OWNER S MANUAL...

Page 2: ...Physical Specifications 4 Unit Description 5 GS Models 6 Installation and Preliminary Testing 6 Load Testing 7 Operation 7 System Batteries 8 Battery System Checkout 9 UPS Monitoring Configurations 9...

Page 3: ...TRATION Locate your warranty registration card in the back of this manual and complete and return within 10 days of receipt of the unit s to register your warranty Failure to register your warranty re...

Page 4: ...igh short circuit current The current capability of each battery system is sufficient to burn large wire or tools very rapidly producing molten metal The following precautions should be observed when...

Page 5: ...00 800 560 50 220 4 0 220 3 6 48 8 20 382 AT1200 1200 840 60 120 11 1 120 10 0 48 7 18 573 GS1200 1200 840 50 220 6 1 220 5 5 48 7 18 573 AT1600 1600 1120 60 120 14 8 120 13 3 72 8 20 765 GS1600 1600...

Page 6: ...er Crest Factor Non Linear Load 3 1 Inverter Waveform Synchronized Computer Grade Sinewave Harmonic Distortion Less than 3 THD at full linear load Inverter Voltage Regulation Static 3 Dynamic 5 with 5...

Page 7: ...Audible Noise 40 dB ANSI Scale A at 3 UNIT DESCRIPTION AT SYCHRONIZED SINEWAVE MODELS 1 Power Switch 2 Alarm Silencer Test momentary rocker switch 3 AC Normal LED Green On when commercial voltage is...

Page 8: ...15P Plug standard or AWG 12 3 SJT AT2300 with NEMA L5 30P Plug 11 Input Fuse Holder Breaker At650 AT800 and AT2300 units use fuse and fuse holder at input AT1200 and AT1600 units use AC circuit break...

Page 9: ...r This testing should be repeated 5 to 10 times 3 Verify that UPS and load functions were proper during this testing see items under INSTALLATION AND PRELIMINARY TESTING for UPS function If all functi...

Page 10: ...y warning IF COMMERCIAL POWER RETURNS BEFORE THE WARNING SIGNAL THERE IS NO NEED TO SHUT DOWN YOUR SYSTEM AT ALL The MINUTEMAN will switch back to normal AC mode operation automatically During normal...

Page 11: ...ystems also offers its own software package Network Manage which functions with Novell Unix OS 2 LAN Manager LAN Server and MacIntosh Operating Systems Network Manager offers many advantages over exis...

Page 12: ...mon problems Do not remove the unit cover or attempt to service this unit There are no user serviceable components inside Unauthorized service will void the warranty COMMON UPS PROBLEMS No normal AC m...

Page 13: ...Other packaging methods can result in damage to the unit Enclose the name and telephone number of the person who can authorize repair charges inside the carton or packing list folder Also include you...

Page 14: ...INDIRECT INCIDENTAL CONSEQUENTIAL OR OTHER TYPES OR DAMAGES RESULTING FROM THE USE OF THIS PRODUCT OTHER THAN THE LIABILITY STATED ABOVE THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR I...

Reviews: