FrameMaker Ver.5.5E(PC) EP3000/EP3010 DIS/REASSEMBLY, ADJUSTMENT
98.05.29
D-34
39-7. PC DRUM CHARGE CORONA/IMAGE TRANSFER CORONA
UNIT
(1) Cleaning of the PC Drum Charge Corona Housing
1. Remove the Imaging Unit.
2. Remove Main Erase Lamp (two screws).
3. Remove one screw and PC Drum charge Corona
Unit.
4. Press the Mesh Holder on the front of the Corona
Unit in the direction of arrow A to remove the Grid
Mesh.
1151D037AA
5. Remove the Cleaning Pad Cover.
6. Remove the End Caps from the front and rear ends
of the Unit.
1139D175AA
7. Remove the Comb Electrode.
NOTE
Use care not to deform the Electrode. When removing
it, first snap off its spring end.
1139D176AA
8. Using a soft cloth dampened with alcohol, wipe the
Housing clean of dirt.
1139D177AA