This function allows the Tech. Rep. to make the various functional tests and adjustments.
<Setting Procedure>
1. Select the particular function to be run.
2. Press the Start key to start the test.
3. Press the Stop key to stop the test.
[Tech. Rep. Mode
Function]
35-4. Settings in the Tech. Rep. Mode
(1) Function
Touch Panel Display
Operation
F1 Paper Passage
A paper passage test is carried out to check for correct sensor
operation without having to wait for the copier to complete warm-
ing up.
<Procedure>
1. Select the paper source from which to feed paper and touch
“Paper Path Sensors.”
2. Press the Start key. This starts a paper take-up and feeding
sequence and the copier shows “1” or “0” depending on the
condition of each sensor.
NOTE
Pressing the Stop key causes the copier to feed the paper out of it
and stop operating; another press of the Start key will resume the
paper take-up and feeding sequence.
F3 Exp. Lamp
Checks to see if the Exposure Lamp lights up properly. (It runs for
30 sec.)
F5 Optimum & AE
Makes the following automatic adjustments: Vg level, Manual
exposure level and AE Sensor optimum exposure level. (It runs for
30 sec.)
<Procedure>
1. Touching “F5” automatically brings you to the next screen (AE
level adjustment screen).
2. Using the
or
key, show the desired number (40 to 60) and
press the Start key. This starts the automatic adjustment
sequence.
3. Touch “Test Copy” to check for image.
F7 Orig. Sensor
Makes an automatic adjustment of the Original Size Detecting
Sensors.
Developer
When “Developer” is pressed, “F8” and “FF” functions are dis-
played and disappear when the corresponding operation has been
completed.
F8 ATDC Adjust
Runs the Developing Unit to agitate developer and makes an auto-
matic adjustment of the ATDC Sensor level. (It runs for 5 min.)
FF F8 + F5
Runs the F8 and F5 operations.
▲
▲
▲