![Minolta Di181 Service Manual Download Page 49](http://html.mh-extra.com/html/minolta/di181/di181_service-manual_1803048049.webp)
FrameMaker Ver.5.5E(PC) Di181 GENERAL, MECHANICAL/ELECTRICAL
99.07.16
M-45
The reference value for the ATDC Sensor is automatically adjusted as detailed below using
the ATDC Sensor Automatic Adjustment mode.
NOTE
I f t h e a u t o m a t i c a d j u s t m e n t m o d e i s r u n a t a t i m e w h e n t h e s t a r t e r h a s n o t b e e n c h a n g e d , i t
c a n r e s u l t i n a w r o n g T / C
r e f e r e n c e v a l u e b e i n g s e t b y t h e c o p i e r . A v o i d c a s u a l u s e o f t h i s
m o d e .
I f t h e s e t t i n g v a l u e h a s b e e n c l e a r e d b e c a u s e o f t h e R A M
b o a r d b e i n g r e p l a c e d , r e t u r n t h e
v a l u e s e t i n t h e T e c h . R e p . m o d e t o t h e o r i g i n a l o n e b e f o r e t h e b o a r d w a s r e p l a c e d .
(1) ATDC Sensor Automatic Adjustment
With the copier set in the ATDC Sensor Automatic Adjustment mode, press the Start key.
The developer is mixed.
The ATDC Sensor converts the reference T/C (5%)
to a corresponding voltage value and outputs it.
Is the output voltage 2.5V?
YES
NO
The voltage input to the ATDC Sensor from the
Master Board at this time is fixed as the reference
voltage.
The voltage input to the ATDC Sensor from
the Master Board is varied:
2.5 V or more: Decrease the voltage.
Less than 2.5 V: Increase the voltage.