FrameMaker Ver5.5E(PC) CF3102/CF2002 TROUBLESHOOTING
02.06.13
T-32
(3)
P-6: Cyan IU failure
(4)
P-7: Magenta IU failure
(5)
P-8: Yellow IU failure
(6)
P-9: Black IU failure
<Detection Timing>
<Action>
Warning Code
Description
P-6
All density readings taken from the density pattern produced on the
Transfer Belt are 0.4 V (AIDC Sensor photoreceiver output) or less
during max. density adjustment (Vg/Vb adjustment).
P-7
P-8
P-9
Relevant Electrical Parts
IU (C)
IU (M)
IU (Y)
IU (Bk)
Image Transfer Belt Unit
Step
Action
1
Select “Image Adjust”
→
“PRT Max Density” and, if the setting value is nega-
tive, readjust.
2
Check the drive transmission portion of the IU and correct as necessary.
3
Clean the AIDC Sensor window if dirty.
4
Clean the contact of the IU connector if dirty.
5
Change IU.
6
Change the Image Transfer Belt Unit.