background image

5. Press

Off

(Yes) button enter into sub-menu item.

[0 kg] is displayed. [0] is blinking.

6. Empty the weighing pan.

7. Press

Off

(Yes) button to start zero point calibration.

The display shows the calibration weight value with all digit blinking [001500.0]

(in this example, 150 kg)

[--C--] is displayed while zero reading is stored.

8. For changing the calibration weight value, press the

Unit

(No) button to edit the

value.

The irst digit is blinking [_015.000 kg].

9. Press

Off

(Yes) button to accept and highlight the next digit.

The 2nd digit is blinking [0_15.000 kg].

7 Calibration and Adjustment

Puro® Compact Scale - Advanced

Minebea Intec

EN-49

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for Puro EF-P1

Page 1: ...5 1 0 0 11 15 2019 Checked on the basis of Puro scale with software version 2 89 Minebea Intec Bovenden GmbH Co KG Leinetal 2 37120 Bovenden Germany Phone 49 551 309 83 0 Fax 49 551 309 83 190 All man...

Page 2: ...spondence concerning this product the type name and release number serial number as well as all license numbers relating to the product have to be cited Note This document is partially protected by co...

Page 3: ...r supply 8 3 4 1 Battery Power 8 4 Device description 9 4 1 Operating 9 4 1 1 Display and operating elements 9 5 Operation 12 5 1 Basic Weighing Function 12 5 1 1 Turn on the device 12 5 1 2 Turn of t...

Page 4: ...arity Calibration Procedure 50 7 3 GEO Geographical Factor Adjustment Procedure 53 7 4 GEO Code Table 55 8 Maintenance repairs cleaning 57 8 1 Repairs 57 8 2 Cleaning 57 8 2 1 Cleaning instructions 57...

Page 5: ...reventing hazards are not followed DANGER Warning of personal injury DANGER indicates death or severe irreversible personal injury which will occur if the corresponding safety measures are not observe...

Page 6: ...and or the environment may occur if appropriate safety measures are not observed Take the corresponding safety precautions Note User tips useful information and notes Puro Compact Scale Advanced 1 In...

Page 7: ...device so that the power plug is freely accessible and the power cord is not an obstacle or trip hazard Do not expose the equipment to aggressive chemical vapors or to unnecessarily extreme temperatu...

Page 8: ...ell as after storage or transport inspect the product visually for signs of mechanical damage The product may not be put into operation if it has visible damage and or is defective Puro Compact Scale...

Page 9: ...vice from aggressive chemical vapors Do not expose the device to extreme moisture over long periods NOTICE Acclimatizing the device Condensation can form on the surfaces of a cold device when it is br...

Page 10: ...n the battery status led lights red while the battery is charging and green when the battery is fully charged For maximum operating time the battery should be charged at room temperature During batter...

Page 11: ...y elements LCD Display Item Description Item Description 1 Busy 12 Auto Taring Symbol 2 Plus 13 Low Average Piece Weight 3 Minus 14 Low Sample Weight 4 Hold symbol 15 Data transfer 5 Zero setting 16 W...

Page 12: ...r tolerance limit Green Weight value is within OK range Yellow Weight value lower tolerance limit 4 1 1 3 Operating elements Button Off T Menu M Mode F Unit Primary Function On Zero Tare M Function Pr...

Page 13: ...the cali bration in pro gress Advances to the previous digit in input process Moves back to previous menu items Decrement the digit Rejects the current setting on the dis play and advances to the next...

Page 14: ...e parameters Is the scale is turned ON for the very irst time then Applications Weighing plus Totalizing manually are active All elements of the display are shown for 2 seconds Press and hold the Off...

Page 15: ...t mode AVERAG Average mode D HOLD D Hold mode Applications Totalization and Auto Tare can be activated via Menu OP FUNC A TARE Auto Tare TOT SET Totalization 1 To select the weighing mode press and ho...

Page 16: ...ch You can toggle the display of a weight value between diferent weight units Possible units are gram g kilogram kg pound lb For taring the container on the scale press the T button if the pan is load...

Page 17: ...plication Percent press the Mode F button until PERCNT is displayed with application icon at bottom of the screen If there is already a reference weight for 100 initialized CLR REF is displayed Otherw...

Page 18: ...ter that go to step 5 If the weight on the pan is 100 reference weight d then REF OK is displayed for 2 seconds Go on at step 7 7 Application is initialized Display shows 100 Reference weight is store...

Page 19: ...is displayed Otherwise PUT 20 for example is displayed then go on at step 4 3 Press the Unit No button to use the stored reference weight 4 Press the Off Yes button to clear the stored PW average pie...

Page 20: ...weight on the pan 2 0 g then LOW REF is displayed But is the weight on the pan 1 8 g then REF ERR is displayed 9 Press the Off Yes button to store the reference quantity sample The display shows PW OK...

Page 21: ...t is within the ACCEPT range Zero Check For comparison of subsequent samples with an initial reference samp le In this case the UNDER limit must be negative value and the OVER li mit must be positive...

Page 22: ...tep 11 3 Press the Off Yes button to set new limits SET LOW set low limit is displayed and the yellow LED for the low limit is on 4 Press the Off Yes button to view the Low limit value The Display wil...

Page 23: ...00 in this example 1 000 kg 8 Repeat until all the digits are correct 9 Press the Off Yes button to accept the low limit value when all digits are blinking again The scale will then display SET HI set...

Page 24: ...edure 13 Press the Off Yes button to establish new check limit value or press the Unit No button to use stored check limit value 14 Place container on the scale in this example 0 527 kg 15 Place sampl...

Page 25: ...yed with application icons and at bottom of the screen CLR REF clear reference will then display 2 Press the Off Yes button to establish a new reference The scale will now display PUT REF put referenc...

Page 26: ...igit back 10 Press the Off Yes button to accept and highlight the next digit 11 Repeat until all the digits are correct 12 Press the Off button to accept the low limit value SET HI will be displayed 1...

Page 27: ...n to establish new check limit value or press the Unit No button to use stored check limit value 17 Place container on the scale in this example 55 0 18 For taring the container on the scale press the...

Page 28: ...tion is activated 20 To view the current check limit reference value In this example low limit value is 80 0 and high limit value is 105 0 press the Mode F button briely at anytime during check weighi...

Page 29: ...20 50 100 200 5 Press the Off Yes button to conirm reference sample quantity If the pan is empty PUT PW put piece weight is shown on the display 6 Put the desired reference quantity on the pan or con...

Page 30: ...blinking _00000 11 Press the Unit button to increase or the Mode F button to decrease the digit value 12 Press the Off Yes button to accept and highlight the next digit The 2nd digit is blinking 0_000...

Page 31: ...procedure like low limit setting The Display will show the high limit value with all digit lashing 00510 0 in this example 510 pcs 18 Press the Off Yes button to accept high limit value The scale is...

Page 32: ...s example 109 pcs 22 Press the T button with NET appear beside the weight value 23 Place sample in the container 24 To view the current check limit reference value In this example low limit value is 5...

Page 33: ...the tare weight e g box container on the scale in this example 0 598 kg 2 For taring the container on scale press the T button NET appears beside the weight value 3 To select the Average Dynamic mode...

Page 34: ...utomatically if the pan is unloaded for about 7 seconds Semi automatic Manual mode 5 2 6 Totalizing and Statistics Mode The Totalizing feature enables manual or automatic totalizing of displayed value...

Page 35: ...nu M button until M E N U is displayed The 1st menu item APLIC shown on display 2 Press the Unit button to move to the next menu item or Mode F button to move to the previous menu item 3 Change menu i...

Page 36: ...n be accumulated 1 Put the irst item on the scale 2 Press the Menu M button to add the weight to accumulation data under manual mode 3 Empty the weighing pan 4 Put another sample on scale and follow s...

Page 37: ...the statistical information in following order Number of weighing done N 7 Totalized value TOTAL 5 225g Minimum value Min 0 47kg 1 Empty the weighing pan 2 Press the Menu M key to display the stored t...

Page 38: ...dded to the same total If the irst load is a gross weight following loads must also be gross weights If the irst load is a net weight following loads must also be net weights 3 Press and hold the T bu...

Page 39: ...the Mode F button until D HOLD is displayed with application icon appear at the left side of the screen 2 Place the load on the scale in this example 0 192 kg If the load is removed the weight value r...

Page 40: ...n will stop blinking 6 Press the T button to tare the container 7 For successive weighing i e continuously adding samples to the container in this example adding 412 g i e total weight become 0 946 kg...

Page 41: ...g in this example APPLIC WEIGH STAB RA value 0 5d 1 Press and hold Menu M button until M E N U is displayed The 1st menu item APLIC shown on display 2 To enter into menu item in this example APPLIC WE...

Page 42: ...ptions Note Some modes units may not be available in all models 6 2 1 Menu Selection APPLIC Enter this menu to select application to be used Only activated units will be accessible with the Mode F Mod...

Page 43: ...2 digit 4d 4 digit FILTER Adaption Filter LOW Less precion short stabilization time MED Normal precion medium stabilization time HI High Precion Long stabilization time A ZERO T Auto Zero Tracking OF...

Page 44: ...NO not restored YES enabled END Leave menu level ZERO R Zero Range 2 zero up to 2 capacity 10 zero up to 10 capacity A TARE Automatic Tare OFF Disable ON 1st stable weight is tared ON ACC Stable loads...

Page 45: ...ton is pressed or the displayed weight changes COM EQU Communication Module OFF Disable BLUE TH Bluetooth Enabled when Bluetooth module Installed WIFI Wi Fi Enabled when WIFI module Installed ETHER N...

Page 46: ...to PC MULTI Multi line single column printout SINGLE Single line printout FEED Paper Feed Setting LINE Move a paper up one line after printing 4LF Move a paper up four lines after printing FORM Form...

Page 47: ...when INT OUT is selected 1 CYC Each display cycle 2 CYC After 2 display cycle 5 CYC After 5 display cycle 10 CYC After 10 display cycle 20 CYC After 20 display cycle 50 CYC After 50 display cycle 100...

Page 48: ...sed to adjust the calibration based on the current location Settings from 0 31 default 12 END Leave menu level TYPE show model name SER NUM show serial number S APPLI Application Menu OFF Unlock ON Lo...

Page 49: ...F Unlock ON Locked S PC COM PC Communication Menu OFF Unlock ON Locked S CAL AD Calibration Adjustment Menu OFF Unlock ON Locked RESET Restore factory setting of current menu OFF Unlock ON Locked END...

Page 50: ...urate weighing results Before performing the calibration be sure to have the appropriate calibration weights Adjust the GEO setting according to your location see table 7 4 CAL ADJ 7 1 CAL Calibration...

Page 51: ...in this example 150 kg C is displayed while zero reading is stored 8 For changing the calibration weight value press the Unit No button to edit the value The irst digit is blinking _015 000 kg 9 Press...

Page 52: ...re correct The Display shows the calibration value with all digit blinking 00100 0 in this example 100 kg 12 When calibration weight value is correct put speciied weight on pan 13 Press Off Yes button...

Page 53: ...enu item until CAL ADJ shows on display 4 Press Off Yes button enter into sub menu item 5 Change menu item until LIN shows on display 6 Press Off Yes button to start zero point calibration 0 kg shows...

Page 54: ...ment at 50 capacity The display will show the linearization weight value at 100 of scale capacity with all digit blinking 00150 0 in this example 150 kg C will be displayed while reading is stored 11...

Page 55: ...7 4 to determine the GEO factor that corresponds to your location Enter into Menu Mode Release the button The display will show the linearization weight value at 100 of scale capacity 00150 0 in this...

Page 56: ...nd blinking 8 If changing the value is needed selection from 0 31 press the Unit button to increase or the Mode F button to decrease the GEO factor value 9 Press Off Yes button to conirm GEO Factor va...

Page 57: ...26 45 10 9 9 8 8 7 7 6 6 5 5 26 45 28 06 10 10 9 9 8 8 7 7 6 6 5 28 06 29 25 11 10 10 9 9 8 8 7 7 6 6 29 25 30 41 11 11 10 10 9 9 8 8 7 7 6 30 41 31 56 12 11 11 10 10 9 9 8 8 7 7 31 56 33 09 12 12 11...

Page 58: ...7 04 23 22 22 21 21 20 20 19 19 18 18 57 04 58 17 23 23 22 22 21 21 20 20 19 19 18 58 17 59 32 24 23 23 22 22 21 21 20 20 19 19 58 17 59 32 24 23 23 22 22 21 21 20 20 19 19 60 49 62 90 25 24 24 23 23...

Page 59: ...form using a damp cloth The weighing platform may not be cleaned using a high pressure cleaner Condensation may form in the device if it is cleaned with water that is too hot or too cold due to temper...

Page 60: ...e so that it can then be recycled Before disposing of or scrapping the product any batteries should be removed and taken to a suitable collection point Please see our T Cs for further information Serv...

Page 61: ...o be within range Err 8 6 Display overlow Weight exceeds 6 digits Err 9 5 Calibration data error Calibration data not present Busy Displayed during tare setting zero set ting printing NO Action not al...

Page 62: ...ng stainless steel 304 weighing platform Ingress protection rating IP43 Display Front and back LCD display with white backlight 1 1 in 28 mm height di gits Checkweighing indi cators 3 LED yellow green...

Page 63: ...t dimension mm w x d x h 310 x 302 x 85 mm Platform size w l 280 x 180 mm Shipment dimension mm w x d x h 370 x 370 x 220 mm Net weight 2 7 kg Shipping weight LF 4 3 kg Product dimension mm w x d x h...

Page 64: ...communication Printer port cable weighing hook lithium battery pack 11 3 Accessories options Option Order No Data Printer YP DP1 Paper for Data Printer YP P1 USB C cable not usable for PC communicati...

Page 65: ...all dimensions in mm inch 11 Technical data Puro Compact Scale Advanced Minebea Intec EN 63 All manuals and user guides at all guides com...

Page 66: ...all dimensions in mm inch all dimensions in mm inch Puro Compact Scale Advanced 11 Technical data EN 64 Minebea Intec All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 67: ...LargeFlat LF 11 Technical data Puro Compact Scale Advanced Minebea Intec EN 65 All manuals and user guides at all guides com...

Page 68: ...all dimensions in mm inch all dimensions in mm inch Puro Compact Scale Advanced 11 Technical data EN 66 Minebea Intec All manuals and user guides at all guides com...

Page 69: ...all dimensions in mm inch SmallTall ST 11 Technical data Puro Compact Scale Advanced Minebea Intec EN 67 All manuals and user guides at all guides com...

Page 70: ...all dimensions in mm inch Puro Compact Scale Advanced 11 Technical data EN 68 Minebea Intec All manuals and user guides at all guides com...

Page 71: ...all dimensions in mm inch all dimensions in mm inch 11 Technical data Puro Compact Scale Advanced Minebea Intec EN 69 All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 72: ...SmallFlatt SF all dimensions in mm inch Puro Compact Scale Advanced 11 Technical data EN 70 Minebea Intec All manuals and user guides at all guides com...

Page 73: ...all dimensions in mm inch all dimensions in mm inch 11 Technical data Puro Compact Scale Advanced Minebea Intec EN 71 All manuals and user guides at all guides com...

Page 74: ...all dimensions in mm inch Puro Compact Scale Advanced 11 Technical data EN 72 Minebea Intec All manuals and user guides at all guides com...

Page 75: ...MAX 14 85 kg Result line Tare value line Net value line Gross value line Mode line Accumulation line Accumulation line Accumulation line Accumulation line If Printx Content Result is ON If Printx Cont...

Page 76: ...2014 35 EU the Non Automatic Weighing Instrument Directive 2014 31 EU 12 3 FCC Note Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to pa...

Page 77: ...Published by Minebea Intec Bovenden GmbH Co KG Leinetal 2 37120 Bovenden Germany Phone 49 551 309 83 0 Email info minebea intec com www minebea intec com All manuals and user guides at all guides com...