3.3
Internal lift-off protection with integrated jack-up
3.3.1
General instructions
No.
Description
1
Upper plate
2
Screw
3
Retaining plate
4
Threaded bolt
5
Threaded bush
6
Lower plate
7
Screw (2×)
8
Nut
9
Washer
The mounting kits are equipped with an internal lift-off protection, i.e. no additional
borings apart from the mounting holes in the vessel foot are required.
Moreover, the vessel can be lifted by turning the threaded bolt (4) (see Chapter
),
e.g., when inserting the load cell.
The two screws (7) are screwed into the lower plate (6).
The screw (2) is screwed into the upper plate (1) and locked with the nut (8).
That way, the safety clearance "A" can be adjusted (see Chapter
).
Maxi FLEX and Maxi FLEXLOCK mounting kits PR 6012/02, ../32, ../42
3 Recommendations for installation
EN-8
Minebea Intec