10 I/O setting (I/O)
This function sets the buttons from F1 to F4 displayed on the weighing screen and the
external control I/O.
10.1 Change to I/O screen
Please switch to I/O screen by the following procedure in weighing screen.
10.2 Setting of the function from F1 to F4
The various input functions from F1 to F4 displayed in the weighing screen are set.
10.2.1
Setting method of functions from F1 to F4 keys
After setting the function from F1 to F4, the display from F1 to F4 in the weighing screen
switches to the setting name.
When F1 is set as [MIXING START] and F2 is set as [BATCH START], the screen shows as
follows.
10.2.2 Function list from F1 key to F4 key
The table below shows the function list that can be set from F1 to F4.
Name
Contents
[OFF]
No setting
[PRINT]]
Print signal is input.
[ZERO CLEAR]
Return the display to the state before zero set and zero tra-
cking when zero set and zero tracking is executed.
[TARE CLEAR]
Return the display to the state of tare weight cancellation
when the tare weight cancellation is executed.
[BATCH START]
The signal of batch start is input.
[DISCHARGE START]
The signal of discharge start is input.
[MIXING START]
The signal of mixing start is input.
[PAUSE]
The weighing operation is stopped temporarily.
[RESTART]
The weighing operation under the temporary stop is restar-
ted.
[FORCED BATCH FINISH] The weighing operation is compulsorily inished.
[FORCED DISCH. FINISH] The discharge operation is compulsorily inished.
[ACCUM. COMMAND]
The accumulation signal is input.
1. Select [MENU].
2. Select [I/O] in the menu screen 1/2.
1. Please tap the button to set from F1 key function to F4 key function in I/O setting
screen 1/6.
2. Select the button to set the function, and tap [OK].