7.6.6
Full open position calibration TYPE2 (FULL OPEN TYPE 2)
The rotating speed or the input pulse of the servo motor necessary for gate full open is
registered, and the full open position is calibrated.
If either is set, the set value is relected in other setting.
Registration of the rotating speed of servo motor
Setting range is 0.250 to 1 000.000 rev.
0.250 rev is set as default.
Registration of input pulse
The setting range is from (Input pulse value per 1 rotation x 0.250) to (input pulse
value per 1 rotation x 1000) pulse.
32 768 pulse is set as default.
7.7 Manual operation (MANUAL CONTROL)
The manual operation of gate is executed. The manual operation can be used when the
system is maintained and conirmed the movement of the gate. The manual operation
screen can be switched by selecting the manual mode on the measurement screen and
shortening the input according to Chapter
.
CAUTION
Damage to the system or malfunctions are possible.
Set each parameter after conirming the speciication of this unit and servo ampliier
and the servo motor used enough.
7.7.1
Switch of manual operation screen
You can switch from weighing screen to position calibration screen by the following
operation.
5. Tap [OK].
1. Select [FULL OPEN TYPE2] in the screen of position calibration.
2. Select [MOTOR REV.], and input the rotating speed of servo motor necessary for gate
full open with ten key.
3. Tap [OK].
4. Tap [INPUT PULSE], and input the input pulse necessary for the gate full open with
ten keys.
5. Tap [OK].
1. Select [MENU].
2. Select [SERVO CALIBRATION] in menu screen 1/2.
3. Select [MANUAL CONTROL] in servo calibration screen.