Note:
-
Use the shielded cable and connect the shield to the F.G. terminal to conform to CE
mark applicable standards.
-
Do not connect the N.C. pin.
4.4.2
Connecting the encoder A-phase pulse and encoder B-phase pulse
Encoder A-phase pulse
SERVO AMP
Encoder B-phase pulse
A3
A4
B3
B4
CSD-918
4.4.3
Connecting the emergency stop signal
Connect the b-contact switch for the emergency stop signal.
Connect it to COM 3 when the emergency stop signal is not used.
When emergency stop signal is used,
B5
Emergency stop signal
COM 3
When emergency stop signal is not used,
B5
Emergency stop signal
COM 3
CAUTION
Warning of personal injury.
The system emergency stop does not work when used with the emergency stop signal
connected to COM 3.
Connect the b-contact switch for the emergency stop signal.
Note:
[SV.ERR EMG] is lit when the emergency stop signal is not connected or set correctly.
Weight Controller CSD-918
4 Wiring
EN-30
Minebea Intec