It displays when the input from the load cell is exceeding the lower input limit of A/
D converter
It displays when the power on original point detection is efective, and while detec-
ting the original point.
Red display of accumula-
ted value and times
The color of the character turns red when the result of the accumulated value and
times exceeds the display range.
19.2.2
Zero error display
Error code
Cause
Action
Z.ERR ZERO
In case of executing ZERO set out of range
of zero set.
Check the range of zero set is appropriate.
Z.ERR A/Z
In case of executing TARE out of range of
tare.
Execute the TARE within the operational
range of tare.
Note:
Tap [ERR.RESET] on top left corner of the screen to cancel the zero error.
19.2.3
Sequence error display
Error code Error
No.
Contents
Measures
SQERR 0
1
Stop compulsorily by inputting the temporary
stop while weighing.
Restart after checking the source of
the temporary stop.
SQERR 1
2
When the condition of SAFETY CHECK is not sa-
tisied.
Check the input of SAFETY CHECK.
SQERR 2
3
When the load value is under even if the supple-
mentary low is executed.
Restart after changing the supple-
mentary low time and count.
SQERR 3
4
When there is contradiction in the amount of the
comparison value.
Solve the contradiction of amount af-
ter checking the setting value.
SQERR 4
5
When the batching time exceeds the limited time. Check the blocking at the batching
gate.
SQERR 5
6
When the discharging time exceed the limited
time.
Check the blocking at the discharging
gate.
SQERR 6
7
When the gross value is smaller than the inal
value in discharge control.
Add the material.
SQERR 7
8
When the net value > (inal value – dribble low)in
the start
Remove the contents in the container.
SQERR 8
9
In controlling the nozzle, when the change of the
load value exceeds the zero band.
Check the position of nozzle.
19 Troubleshooting
Weight Controller CSD-918
Minebea Intec
EN-201
Summary of Contents for CSD-918 Series