Note:
The open rate is a relative value to the full open position at the gate.
In this control method, the gate reaches the open rate set before at once, and is
maintained until the completing time.
11.2.3
Coarse low ixed open rate (weight)
The open rate of the gate in full low and the weight are set.
The open rate is a relative value to the full open position at the gate.
The setting range of open rate of the gate is from [0.000 %] to [100.000 %]
The setting range of the weight is from [0] to [999 999].
[50.000 %] is set as default for open rate of the gate, and [1 000] for the weight.
W
eighing
Time[ms]
O
pen
rat
e[
%]
Time[ms]
Note:
-
The open rate is a relative value to the full open position at the gate.
-
In this control method, the gate reaches the open rate set before at once, and is
maintained until the completing time.
1. Select [FULL FLOW] in coarse low screen, and select [FIXED OPEN (TIME)], and then
tap [OK].
2. Tap [FIXED OPEN (TIME)] in coarse low screen to inputting the each value.
3. Select [TIME], and input the completing time of coarse low by ten keys, and then tap
[OK].
4. Select [OPEN], and input the open rate of the gate by ten keys, and then tap [OK].
11 Weighing mode
Weight Controller CSD-918
Minebea Intec
EN-99