Condition
Pin No.
NET WEIGHT
OUTPUT5
ZERO
OUTPUT6
HOLD
OUTPUT7
ERROR
OUTPUT8
Z-BAND
OUTPUT9
F. (Coarse) FLOW/S1
OUTPUT10
M. (Middle) FLOW/S2
OUTPUT11
D. (Fine) FLOW/S3
OUTPUT12
OVER/S4
OUTPUT13
[MONT]
▼ Conirmation of load cell output voltage
14.7 Conirmation of load cell output voltage
In the conirmation of the load cell output voltage, the load currently applied to the load
cell is converted to mV/V.
If an unknown load cell is used, execute calibration based on the load cell output value
with an actual weight for the tare weight and maximum load.
[MONT]
[ON-OFF]: Quit check mode
With BCD output
[BCD]
Conirmation of BCD output
With analog output
[AOUT]
Conirmation of analog output
No BCD or analog output
[ROM]
Conirmation of ROM version
Press the [F/ENTER] key from the [MONT] display. The current load cell output
voltage display blinks.
Weight indicator CSD-903
14 Check mode
EN-128
Minebea Intec