When [OL or unstable] is selected, the FINISH signal turns OFF when the display switches
to OL or –OL or when the stable signal output turns OFF.
When the [Near zero] is selected, the FINISH signal turns OFF when the near zero signal is
output.
The default is [No condition].
12.17 Discharge operation setting after weighing inish
This sets the operation for discharge after weighing is inished.
12.17.1 Discharge start at weighing inish
Set the discharge operation to start when weighing inishes by SQ function SQF-45.
The default is [Invalid].
12.17.2 Discharge monitor timer
Set the timer that monitors the time from discharge start to discharge inish by SQ
function SQF-46.
Setting range: 0000 to 9999; Unit: 1 s; 0000: OFF
The default is [0000].
12.17.3 Discharge gate close delay time
Set the time to gate closing when the weighing value fulils the near zero condition by SQ
function SQF-47.
Set the timer that monitors the time from discharge start to discharge inish by SQ
function SQF-46.
Setting range: 0000 to 9999; Unit: 0.01s; 0000: OFF
The default is [0000].
12.17.4 Discharge inish output time
Set the output time for the discharge inish signal by SQ function SQF-48.
Setting range: 0000 to 9999; Unit: 0.01s; 0000: OFF
The default is [0000].
12.17.5 Tare weight cancellation at discharge inish
Set tare weight cancellation clear when discharge inishes by SQ function SQF-49.
The default is [Invalid].
12.18 Accumulation clear
C function clear is executed by S function CF-98.
[SQF-98]
[ACCUCLR]
1. Clear the accumulation times and the accumulation value.
2. Press the [F] key to display[SQF-98]. [ACCUCLR] blinks.
3. Press the [ON-OFF] key to discontinue memory clear.
The display switches to stand-by mode without clearing the memory.
12 Various SQ function data functions
Weight indicator CSD-903
Minebea Intec
EN-121