51
7-22 Codabar
Read:
Format
Start
Data digits (variable)
Check digit (1 digit, optional)
End
Check digit verification: The check digit is made as the sum module 16 of the numerical values of all data
digits.
Check digit transmission: By setting Enable, check digit will be transmitted.
Max./Min. code length: Refer to Max./Min. code length of
7-17 Code 39(Code 32, Trioptic Code 39)
.
Code ID setting: Refer to Code ID setting of
.
Insertion group selection: Refer to Insertion group selection of
.
Start/End type: Codabar has four pairs of Start/End pattern; you may select one pair to match your
application.
Start/End transmission: Refer to Start/End transmission of Code 39.
Start/End character equality: By setting Enable, the start and end character of a Codabar barcode must
be the same.
Multiple-scan setting
Single-scan setting
Option barcode
Option
Alpha. entry
Read
Disable
00
Enable
01*
*
Check digit verification
Disable
00*
*
Enable
01
Check digit transmission
Disable
00*
*
Enable
01
Max. code length
00-99
00-99
00*
*
Min. code length
00-99
00-99
00*
*
Code ID setting
00-FF
16
(ASCII)
00-FF
16
<N>*
*
Summary of Contents for MP82 Series
Page 1: ...MP82xx Image Platform User Manual Version MP82xx_UM_EN_V1 1 5...
Page 2: ......
Page 4: ...ii...
Page 13: ...7 Figure 4 6 Field of view Horizontal Figure 4 7 Field of view Vertical...
Page 95: ...89 PDF417 12 890ab xyz MicroPDF417 23 mdo QR code 1234567890ABCD XYZ Data Matrix 123890abc mdo...
Page 102: ...96 14 Configuration alphanumeric entry barcode...