Minarik MM23001C Quick Start Manual Download Page 1

3.80 [97]

0.74 [19]

1.75 [44]

3.58 [91]

1.28 [33]

0.96 [24]

1.60 [41]

0.19 [5]

0.64 [16]

0.19 [5]

4.30 [109]

DECEL

ACCEL

S3

S2

INHIBIT

C504

MIN SPD

MAX SPD

TORQUE

180

90

SW502

IL501

CL

MOV501

L1

L2

F1

MOV503

SW501

F2

SCR501

D501

R

50

2

SO502

+

METER

-

D502

A2

M

O

V

50

2

D503

A1

IR COMP

IC501

C502

S1

C

503

IC

50

2

C501

R

50

1

SCR502

115         230

SCR, Adjustable Speed Drive

for DC Brush Motors

Q U I C K   S T A R T   G U I D E

MM23001C 

D I M E N S I O N S

S P E C I F I C A T I O N S

1.  Turn the speed adjust potentiometer to “0” (full CCW)

2.  Apply AC line voltage

3.  Set the POWER switch to the ON position

4.  Slowly advance the speed adjust potentiometer clockwise (CW).  The   

motor slowly accelerates as the potentiometer is turned CW.  Continue
until the desired speed is reached.

5.  Set the POWER switch to the OFF position to coast the motor to a stop.

S T A R T U P

M I N A R I K   D R I V E S

w w w . m i n a r i k d r i v e s . c o m

14300 De La Tour Drive, South Beloit, IL 61080; Phone:  (800) MINARIK (646-2745); Fax:  (815) 624-6960

Document Number: 250-0387, Revision 1; Printed in the U.S.A. - May 2006 

Copyright 2004 by Minarik Drives - All rights reserved. No part of this document may be reproduced or transmitted in any form without written permission from
Minarik Drives. The information and technical data in this document are subject to change without notice. Minarik Drives and its Divisions make no warranty of
any kind with respect to this material, including, but not limited to, the implied warranties of its merchantability and fitness for a given purpose. Minarik Drives and
its Divisions assume no responsibility for any errors that may appear in this document and make no commitment to update or to keep current the information in
this document.  kc0604

AC Line Voltage                                   115 VAC or 230 VAC  50/60Hz, single phase
Armature Voltage (115 VAC Input)                                                          0 - 90 VDC
Armature Voltage (230 VAC Input)                                                        0 - 180 VDC
Armature Current                                                                                           10 

1

A

Form Factor                                                                              1.37 at base speed
HP Rating (90 VDC)                                                                                1/8 - 1 HP
HP Rating (180 VDC)                                                                              1/4 - 2 HP
Field Voltage (115 VAC Input)                        50 VDC (F1 to L1); 100 VDC (F1 to F2)
Field Voltage (230 VAC Input)                      100 VDC (F1 to L1); 200 VDC (F1 to F2)
Max. Field Current                                                                                        1 ADC
Accel. Time Range:

for 0 - 90 VDC Armature Voltage                                                   0.5 -11 seconds
for 0 - 180 VDC Armature Voltage                                                0.5 - 22 seconds

Decel. Time Range:

for 0 - 90 VDC Armature Voltage                                 coast to a stop - 13 seconds
for 0 - 180 VDC Armature Voltage                               coast to a stop - 25 seconds

Analog Input Voltage Range (signal must be isolated; S1 to S2):

for 0-90 VDC Armature Voltage                                                         0 - 1.4 VDC
for 0-180 VDC Armature Voltage                                                       0 - 2.8 VDC

Requires heatsink 223-0159 when above 5 Amps