- 5-18 -
Resetting UV Lamp Irradiation Time
After replacing the UV lamp, reset the irradiation time stored in this printer.
STEPS:
1.
Select the [UV LAMP] from the mainte-
nance functions.
Enter the [MAINTENANCE] from the FUNCTION
menu.
2.
Touch the [ENTER].
3.
Touch the JOG [ ] or [ ] to select the
[INIT TIMER].
4.
Touch the [ENTER].
5.
Touch the [ENTER] again.
The irradiation time is initialized.
6.
When the operation completes, the mes-
sage shown on the right is displayed.
7.
Touch the [END] twice, to return to the
LOCAL mode.