In Case Sefective Printing Is Not Resolved
When the station interior is severely contaminated or defective printing is not resolved
after executing the head cleaning function (
Operation manual P.2-20).
Clean the suction nozzle and cap using the cleaning kit as follows,
Washing liquid, Gloves, Cleaning swab, goggles
• When cleaning the ink station and head, be sure to wear the supplied
goggle and gloves since you may get ink in your eyes.
• Do not use alcohol or water.
• Do not move the carriage out of the capping station by hand. Use the
appropriate operation key to move the carriage.
The examples of defective printing
These following examples indicate improper head (nozzle) firing by dust, which effect
printing. Confirm the nozzle condition periodically before or during outputting not to use in
such as this condition. The nozzle condition can be confirmed with [test print] in this plotter.
Deflection
Nozzle out
Ink dropping
Satellite