5-12
Chapter 5 Troubleshooting
Error messages
When an error message is displayed, eliminate the error according to the chart below.
If the same error message appears again, contact your dealer or an office of MIMAKI to call for service.
Message
Cause
Measures
ERROR 04
PARAM ROM
The PCB is defective.
• Turn off the power button to the machine
and turn it on after a while.
• If the same error message appears
again, contact your local distributor to call
for service.
ERROR d0b
HD CONNECT [23456789ABC]
Abnormal connection of the print head
ERROR d0c
HD THERMIS
[23456789ABC]
Abnormal connection of the print head
ERROR d1b
B MEMORY
[123456789ABC]
The print head has been broken.
ERROR 108
HD TYPE
[123 ]
ERROR 122
CHECK : SDRAM
[123 ]
Not found PRAM board.
ERROR 128
HDC FIFO OVER
Control circuit board is defective.
ERROR 128
HDC FIFO UNDER
ERROR 128
BATTERY EXCHANGE
The battery life end of the internal clock is
detected.
• Contact your local distributor to call for
service.
ERROR 12a
HDC SPEED [123 ]
Ink discharge control error
• Turn off the power button to the machine
and turn it on after a while.
• If the same error message appears
again, contact your local distributor to call
for service.
ERROR 12a
HEAD ROM WR
Head control error
ERROR 12e
HeadFaild /HDC[**]
The print head has been broken.
ERROR 130
HD DATA SEQ
Control circuit board is defective.
ERROR 148
E-LOG SEQ
ERROR 151
Main PCB V1R2
An error occurred in the main power.
ERROR 152
Main PCB V2R5
ERROR 153
Main PCB V3R3
ERROR 154
Main PCB V05
ERROR 155
Main PCB V36-1
ERROR 156
Main PCB V5B
ERROR 157
Main PCB VTT
ERROR 158
Main PCB V36-2
ERROR 15F
HEAD DRIVE HOT
The temperature abnormality of control cir-
cuit board has been detected.
ERROR 16e
Main PCB V3R3B
An error occurred in the main power.
ERROR 171
NEW HEAD CONNECT
Connection of a new head was recognized.