- 5.16 -
When not in use the plotter over the long term [CUSTODYwash]
When not in use the plotter over a week, perform “CUSTODYwash” function to clean the head
nozzle and ink discharge way.
After performing the function, store the plotter.
Cleaning tools
•
Cleaning Solution RS (SPC-0336), Pipette
•
Glove, Goggle
STEP
1.
Press the [FUNCTION] key.
2.
Press the [ ] and [ ] key until the display
gives the indication [MAINTENANCE].
3.
Press the [ENTER] key.
[STATION] is displayed.
4.
Press the [ ] and [ ] key until the display
gives the indication [CUSTODYwash].
5.
Press the [ENTER] key.
The carriage moves to the platen.
6.
Open the front cover.
7.
Holding the projections at both ends, draw out
the wiper.
8.
Remove the ink at the wiper and the bracket
using a cotton bud dampened with cleaning
fluid RS.
•
If dirt of curl is serious, replace the wiper with a
new one. At the time of replacement, be sure to
terminate the plotter operation and follow the
wiper replacement procedure.
page 5.5
FUNCTION
SET UP
< ENT >
FUNCTION
MAINTENANCE
< ENT >
MAINTENANCE
STATION
< ent >
STATION
MENT : CUSTODYwash
Wiper Cleaning
COMPLETED
:ent
Summary of Contents for JV3-130 SP II
Page 2: ......
Page 34: ... 1 16 ...
Page 120: ... 5 32 ...
Page 130: ... 6 10 ...
Page 136: ... A 6 ...
Page 137: ......
Page 143: ......
Page 144: ...Printed in Japan MIMAKI ENGINEERING Co Ltd 2004 ...