- 4.32 -
Execute the flushing and cleaning regularly [ROUTINE CTR]
This function allows for the pigment ink for textile (TPig).
Set time limits on the flushing and cleaning functions at regular time intervals to avoid nozzle
clogging and clean off dust on the nozzle surface.
Routine Flushing
The routine flushing function is executed with the power on.
Time set by the hour is available for 1 to 24 hrs with this function turns on.
STEPS:
1.
Select [ROUTINE CTR] from [MAINTENANCE].
(See page 4.3)
2.
Press the [ENTER] key.
3.
Press the [ENTER] key.
4.
Press the JOG key [ ] and [ ] to select [ON] or
[OFF] of the [ROUTINE FLUSHING].
Here, select [ON].
5.
Press the [ENTER] key.
6.
Press the JOG keys [ ] and [ ] to select time
interval.
7.
Press the [ENTER] key.
8.
Press the [END] key three times.
The menu returns to the LOCAL mode.