- 3.7 -
Cleaning the nozzle [Nozzle Cleaning]
Clean up the nozzle as for nozzle clogging.
If nozzle clogging cannot be resolved even after cleaning several times, execute the [Ink Filling]
function. (
page 5.11)
If this error cannot be resolved with these functions, contact the dealer.
• Two colors (two cartridges) per head are used. If the remaining
amount of one ink is extremely greater than another ink's amount, it
may flow into the cartridge which has lesser ink to make their ink-head
even.
Execute the [Ink Filling] function (P.5-11) if the inks are mixed.
• Operate it in the head only with the nozzle clogging.
Cleaning Tools :
• Cleaning liquid bottle kit A29 (SPC-0137 : Option)
• Syringe
STEPS:
1.
Press the [FUNCTION] key in the LOCAL mode.
2.
Press the XY [ ] or [ ] keys to select [MAINTE-
NANCE].
3.
Press the [ENTER] key.
[Station] is displayed.
4.
Press the XY [ ] or [ ] keys to select [Nozzle
Clean].
5.
Press the [ENTER] key.
The table moves backward, the Y-bar moves to the top, the
wiper moves forward, and the carriage moves on the table.
FUNCTION
SETUP
< ENT >
Color May Mix Up
Continue OK?
: ent
FUNCTION
MAINTENANCE
< ENT >
MAINTENANCE
Station
< ent >
Station Maint
Sel
: Nozzle Clean
MAINTENANCE
List
< ent >
Summary of Contents for DM2-1810
Page 2: ......
Page 18: ...xiv...
Page 72: ...3 20...
Page 98: ...5 18...
Page 108: ...6 10...
Page 116: ...A 8...
Page 117: ...A 9 Function flowchart...
Page 119: ...A 11 Filling 00 00 00 Display remaining time Function flowchart...
Page 129: ...A 21 TYPE Refresh Level3 TYPE mm inch mm X Level0 Level3 X inch Function flowchart...
Page 143: ...A 35...
Page 144: ...D201256 1 10 02082005...
Page 145: ......
Page 146: ...PrintedinJapan MIMAKI ENGINEERING Co Ltd TI TM...