6-27
6
Mai
ntenanc
e
Setting Regular Operations
Various regular operations are performed with the power ON to prevent problems, such as ink coagulation, from
occurring (Regular settings). For the regular settings, the following items can be set:
z
Default value for each ink
Set Item
Set Value
Overview
ROUTINE WIPING
SCAN COUNT
0 to 9,990 times
When the set number of times scanning is performed has been
reached during a printing operation, the nozzle face is wiped
and dew condensation is removed.
TEMP.
Difference
1 ~ 60
℃
When the difference between the set temperature of the print
heater and the ambient temperature has exceeded a specified
temperature during a printing operation, the nozzle face is wiped
and dew condensation is removed.
REFRESH
OFF/1 to 168
*1
hours
*1. The default setting differs, depending on the type of ink you use. The default setting for each ink is as follows:
The interval between each refreshing operation is set.
PUMP TUBE WASH
The interval between each PUMP tube washing operation is set.
CLEANING
The interval between each cleaning operation is set.
Ink Type
Refreshing
PUMP Tube Washing
Cleaning
SS21
4 hours
48 hours
OFF
ES3
48 hours
168 hours
OFF
• When the message on the right is displayed, the operations other
than [ROUTINE WIPING] in the regular settings are not performed.
Perform the operations described on P.6-37 as necessary.
• When you turn off the power switch on the front side of the machine,
check the state of the waste ink tank.
• If the connection unit is connected to the cutter unit when the set
time shown above has past, it displays a screen shown on the right,
and regular operations cannot be executed (Reminder buzzer
sounds periodically).
In this case, execute pump tube washing / cleaning, or switch the connection unit to the printer mode
using origin setting (
P.2-33) in the printer mode, and execute regular operations.
< LOCA L . 1 >
[ # 0 1 ]
! WAS T E T ANK
< LOCA L . 1 > ! RTN
[ # 0 1 ]
WI DTH : 1 0 0 0mm
Summary of Contents for CJV30-100
Page 15: ...xiv How to Read this Manual...
Page 16: ...xv...
Page 158: ...Other Convenient Functions 4 48 12 Press the key...
Page 261: ...8 29 Function Flowchart 8 Appendix...
Page 269: ...8 37 Function Flowchart 8 Appendix...
Page 272: ...8 40...
Page 273: ...D201873 11 26092008...