Chapter 8 Dealing with Problems
165
7
Use
to select [SENSOR OFS], then press the [ENTER/HOLD] key.
• After (one) register mark has been detected, auxiliary lines are cut for the register mark center
lines together with five auxiliary lines at 0.2 mm intervals on either side of the center lines.
B direction
A direction
+0.2 mm offset from register mark center
lines in both A and B directions
8
Use
to enter the A direction correction value (mm) and
to enter the B direction
correction value (mm), then press the [ENTER/HOLD] key.
• If the offset is +0.2 mm, enter "-0.2".
• The correction amount is saved and the system returns to local mode.
• The settings are retained even when the power is turned off.
• The sensor offset set using this operation will not be reset by [SETUP RESET].
Investigating the Cause of Cutting Failures
The machine cuts a sample stored in the unit to troubleshoot problems when data cannot be cut properly.
Executing a sample cut will clear any data saved in the receive buffer.
1
Press the [FUNCTION] key in local mode.
2
Use
to select [SAMPLE CUT], then press the [ENTER/HOLD] key.
3
Use
to select the sample data.
• There are two sample types: "Cut" and "Logo".
• If "Cut" is selected, proceed to Step 5.
Sample
Cut
Logo
4
When cutting with "Logo" selected, press
to specify the scaling factor (1 to 999 %).
5
Press the [ENTER/HOLD] key to start cutting.
• Cutting starts.
8
Summary of Contents for CG-100AR
Page 39: ...Chapter 1 Before Using This Machine 39 2 Shut down the computer connected to the machine 1 ...
Page 76: ...Chapter 2 Cutting 76 ...
Page 98: ...Chapter 3 Cutting Data with Register Marks 98 ...
Page 131: ...Chapter 4 Helpful Tips 131 4 Press the END key several times to exit 4 ...
Page 132: ...Chapter 4 Helpful Tips 132 ...
Page 133: ...Chapter 5 Settings This chapter Describes the individual settings FUNCTION 134 SET UP 135 ...
Page 150: ...Chapter 6 Maintenance 150 ...
Page 158: ...Chapter 7 Options 158 ...
Page 178: ...Chapter 9 Appendix 178 ...
Page 182: ...MEMO ...