1-26
Setting the Vacuum
Interlock between Remote Key and Vacuum Key
The vacuum key can be turned on/off automatically using the remote key.
If a cutting operation is performed without activating the vacuum, the workpiece may float and hinder the cutting
operation.
This symptom can be prevented by selecting "REMOTE ON".
This function is available from firmware version V1.50.
1
Select [PLOT SETTING] of the set up menu.
(1)Press the
key in LOCAL.
(5)
Press
to select [SET UP] and press the
key.
(6)
Press
to select [PLOT SETTING].
(7)
Press the
key.
2
Press the jog key
or
to select [BEFORE
PLOT], and ress the
key.
3
Press the
key.
4
Press the jog key
or
to select [REMOTE
ON].
• Set values: N/C , REMOTE ON
5
Press the
key.
• Press
if you do not want to save the setting.
6
Press the
key twice for terminating this function.
Item
Set value
REMOTE ON
When the remote mode is selected by pressing the remote key, the
vacuum is automatically turned on.
When the offline mode is selected using the remote key, the vacuum is
turned off.
N/C
You can turn on/off the vacuum using the vacuum key on the operation
panel.
FUNCTION
< P LOT SE T T I NG>
BE FORE P LOT
[ ENT ]
< BE FORE P LOT >
VACUUM ON : N / C
N
< BE FORE P LOT >
VACUUM ON : REMOT E ON
Summary of Contents for CFL-605RT