1-25
1
Set
u
p
5
6
6
Setting the Vacuum
Sets the vacuum operation when the vacuum is used.
Enabling / Disabling the Vacuum Automatic OFF Function
1
Select [PLOT SETTING] of the set up menu.
(1)
Press the
key in LOCAL.
(2)
Press
to select [SET UP] and press the
key.
(3)
Press
to select [PLOT SETTING].
(4)
Press the
key.
2
Press the jog key
or
to select [AFTER
PLOT], and ress the
key.
3
Press the jog key
or
to select [VACUUM],
and ress the
key.
4
Press the jog key
or
to select setting.
• Set values: N/C , AUTO OFF
5
Press the
key.
• Press
if you do not want to save the setting.
6
Press the
key twice for terminating this function.
Item
Set value
AUTO OFF
*1
*1. The vacuum cannot turn off automatically if automatic head retraction is OFF.
If automatic head retraction is set to available, the vacuum turns off automatically
after head retraction.
N/C
Vacuum remains on after head retraction.
• If replace the sheet during continuous cut of register mark, it automatically turns off the vacuum
regardless the setting of the head automatic retraction.
FUNCTION
< A F T ER P LOT >
AUTO V I EW: OF F
< A F T ER P LOT >
VACUUM
: N / C
< A F T ER P LOT >
VACUUM
: AUTO OF F